Logtag® UTRED 30-16 RECOMMENDED VACCINE MONITORING LOGGER
30 day logger with display
Logtag® UTRED 30-16 connects to a computer USB port for easy configuration by the user for a wide range of recording and alert conditions. Upon download, it automatically generates a fully detailed PDF report with the option to download the data using the freely available LogTag Analyzer software for a more detailed analysis. A red alarm indicator together with X shown on display provides an immediate indication – without access to a PC – if any readings are outside the limits specified at the time the unit was configured.Automatically generates an encrypted LogTag data file – for a more detailed analysis and to comply with FDA CFR21 Part 11.
- New large easy-to-read display.
- Read Current temperature and latest Min-Max temperature at a glance.
- Check and reset Min-Max temperature reading at any time.
- Audible alarm and flashing red LED signals a temperature alarm.
- View alarm status for up to 30 days at a glance.
- Powered via a standard plug-in power adaptor and a USB cable.
- Can be powered by 2x AAA Alkaline batteries (user replaceable) if not external powered.
- Download data via LogTag Analyzer or as a PDF (no software required).
Product Model | UTRED30-16. |
External Sensor Measurement Range | -40°C to +99°C (-40°F to +210°F). |
Operating Temperature Range | -30°C to +60°C 0 – 99 % RH (non-condensing) |
Storage Temperature Range | -10°C to +40°C (32°F to +104°F). |
Rated Temperature Resolution | Better than 0.1°C (0.2°F) for -30°C to +60°C (-22°F to +140°F). Better than 0.2°C (0.4°F) for -40°C to -30°C (-40°F to -22°F). Better than 0.5°C (0.9°F) for +60°C to +99°C (+140°F to +210°F). LogTag Analyzer currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Rated Temperature Reading Accuracy | Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F). Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F). Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F). Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F). |
Probe Connectivity | Up to 2 |
Probe Compatibility | All ST100 precision thermistor external probes can be interchangeably connected to the UTRED30-16. Please refer to the Accessories section for compatible External Probes. Different probe models can be used for each channel. Not compatible with ST10 sensors. |
Sensor Reaction Time | Typically less than 2 minutes(T90) in moving air (1m/s) for ST100S type |
Recording Capacity | 32,000 total log memory. Provides 16,000 temperature readings per channel. Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics. |
Sampling Interval | Configurable from 30 seconds to 18 hours. (Typically 5 minute logging) |
Alarms | Up to 6 individually configurable alarms for each channel. Possible to set alarms separately for Channel 1 and Channel 2. |
Logging Start Options | Push button start or specific date & time. Optional start delay. |
Download Time | Typically with full memory (32,000 readings) in less than 20 seconds. |
Environmental | IP61 (when vertically mounted or hung with USB dust-cap in place). |
Power Source | 5V via micro USB socket or 2 x 1.5V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only). |
Battery Life | AAA battery up to 12 months – if unit is operated without power supply. |
Real Time Clock | Built-in real time clock. Typical accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C). |
Connection Interface | USB 2.0 / Micro USB Socket. |
Standard Remote Probe Cable Lengths | Standard: 1.5m (4’11”). Extended: 3m (9’10”) (recommended maximum). |
Remote Probe Cable Type | PTFE (FDA food contact rated) coaxial. |
Size | 141mm(H) x 72mm(W) x 18mm(T). |
Weight | 156g with AAA batteries, (132g – excluding probe and AAA batteries). |
Case Material | Polycarbonate. |
- Overview
-
Logtag® UTRED 30-16 RECOMMENDED VACCINE MONITORING LOGGER
30 day logger with display
Logtag® UTRED 30-16 connects to a computer USB port for easy configuration by the user for a wide range of recording and alert conditions. Upon download, it automatically generates a fully detailed PDF report with the option to download the data using the freely available LogTag Analyzer software for a more detailed analysis. A red alarm indicator together with X shown on display provides an immediate indication – without access to a PC – if any readings are outside the limits specified at the time the unit was configured.Automatically generates an encrypted LogTag data file – for a more detailed analysis and to comply with FDA CFR21 Part 11.
- New large easy-to-read display.
- Read Current temperature and latest Min-Max temperature at a glance.
- Check and reset Min-Max temperature reading at any time.
- Audible alarm and flashing red LED signals a temperature alarm.
- View alarm status for up to 30 days at a glance.
- Powered via a standard plug-in power adaptor and a USB cable.
- Can be powered by 2x AAA Alkaline batteries (user replaceable) if not external powered.
- Download data via LogTag Analyzer or as a PDF (no software required).
- Technical specifications
-
Product Model UTRED30-16. External Sensor Measurement Range -40°C to +99°C (-40°F to +210°F). Operating Temperature Range -30°C to +60°C
0 – 99 % RH (non-condensing)Storage Temperature Range -10°C to +40°C (32°F to +104°F). Rated Temperature Resolution Better than 0.1°C (0.2°F) for -30°C to +60°C (-22°F to +140°F).
Better than 0.2°C (0.4°F) for -40°C to -30°C (-40°F to -22°F).
Better than 0.5°C (0.9°F) for +60°C to +99°C (+140°F to +210°F).
LogTag Analyzer currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F).
Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F).
Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F).
Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F).Probe Connectivity Up to 2 Probe Compatibility All ST100 precision thermistor external probes can be interchangeably connected to the UTRED30-16.
Please refer to the Accessories section for compatible External Probes. Different probe models can be used for each channel. Not compatible with ST10 sensors.Sensor Reaction Time Typically less than 2 minutes(T90) in moving air (1m/s) for ST100S type Recording Capacity 32,000 total log memory. Provides 16,000 temperature readings per channel.
Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics.Sampling Interval Configurable from 30 seconds to 18 hours. (Typically 5 minute logging) Alarms Up to 6 individually configurable alarms for each channel.
Possible to set alarms separately for Channel 1 and Channel 2.Logging Start Options Push button start or specific date & time. Optional start delay. Download Time Typically with full memory (32,000 readings) in less than 20 seconds. Environmental IP61 (when vertically mounted or hung with USB dust-cap in place). Power Source 5V via micro USB socket or 2 x 1.5V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only). Battery Life AAA battery up to 12 months – if unit is operated without power supply. Real Time Clock Built-in real time clock.
Typical accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).Connection Interface USB 2.0 / Micro USB Socket. Standard Remote Probe Cable Lengths Standard: 1.5m (4’11”).
Extended: 3m (9’10”) (recommended maximum).Remote Probe Cable Type PTFE (FDA food contact rated) coaxial. Size 141mm(H) x 72mm(W) x 18mm(T). Weight 156g with AAA batteries, (132g – excluding probe and AAA batteries). Case Material Polycarbonate. - Downloads