V-sensor Pressure – Volume Alarm Transmitter
The V-Sensors are high precision differential low air pressure and volume transmitters, PID controllers and have one volt free change over alarm relay and a buzzer on board. They are for use in laboratory, clean room installations containment facilities and commercial and industrial ventilation systems.They have overload protection and auto-zero.
The Transmitters have a linear output to pressure or air volume. They work with all CMR duct mounted Veloprobes, Flowprobes, Flowgrids and Venturis. One red and one green led can indicate high or low alarm on the keypad front panel. Signal outputs of 0..10V and 4..20mA as well as modbus rtu is fitted for connection to the BMS, SCADA or PLC’s. There is an additional modbus rtu connection to operate a variety of remote alarm display panels.
Power supplies 24Vdc, 24Vac, 110Vac and 230Vac are available. CE conformity certificates as well as calibration certificates traceable to International Standards (UKAS) are supplied. as standard. All commissioning configurations can be done via the standard operator’s keyboard.
- Ultra low pressure and volume measurement
- Traceable Calibration Certificate is included
- High accuracy and repeatability
- Linear pressure or air volume output
- Both measurement and PID control output
- Two modbus for monitoring and remote display
- One alarm relay, buzzer and LED indicators
- Auto Zero and overload protection is standard
- Operator keyboard display for all functions
- Two Modbus rtu, 0..10V and 4..20mA outputs
- IP65 enclosure with easy mount wall bracket
- 24 month warranty
- 30 Years field application experience
V-Sensor |
|
Measurement Range | Any Range from 0-25Pa or -/+25Pa up to 0-7500Pa or -/+7500Pa |
Overload Capacity | Ranges 25Pa – 150Pa up to max 1200Pa if over pressure protection is off. Ranges from 200Pa – 7500Pa up to max 10 times of range if over pressure protection is off. |
Media | Non corrosive gases such as Air, N2, O2, Co2, N2O and inert gases |
Diaphragm Unit | Beryllium Copper suitable for high concentration of Formaldehyde – Stainless Steel on request. |
AC Power Supplies Transformer Isolated |
24 Vac 50/60Hz 198mA. Internal Fuse 300mA Auto-Reset 110Vac 50/60Hz 40mA. Fuse 315mA Wickmann. 230Vac 50/60Hz 20mA. Fuse 315mA Wickmann |
DC Power Supplies | 24 Vdc (19 to 31Vdc) smoothed 118mA Internal Fuse 300mA Auto-Reset. |
Voltage Output Signal | 0-10V (0 to100% of Range) RL = 5kOhm min.Other output signals (e.g. 2-10V) or PID loop control is programmable via the keyboard. |
Current Output Signal Relay Output 1A 24Vdc |
4-20mA (0 to100% of Range) RL = 500 Ohm max (0-20mA) or PID control is programmable via keyboardOne Alarm changer over volt free contact is user programmable |
2 x Modbus rtu Connection | 2 x Output Signal, Alarm Status, Alarm Thresholds and Alarm Timers are all readable as Modbus rtuCommands. Modbus register assignments to read and write are available in user manual. |
Hysteresis/Repeatability | 0.1% Typical of Full Scale. |
Linearity (Accuracy) | +/- 0.25% of Full scale = > 100 Pa and 0.25Pa < 100Pa. |
Zero Drift | 0.05%K (+10°C to +50°C) – Automatically corrected to 0.0 if Auto-Zero function is enabled |
Operating Temperature | -10°C to +70°C. |
Mounting Position | Vertical. |
Weight | 0.6 kg in ABS Housing. |
Electrical Connections | ABS Housing: 1 x M20 Gland and 1 x M12 Gland and internal removable Screw Terminals. |
- Overview
-
V-sensor Pressure – Volume Alarm Transmitter
The V-Sensors are high precision differential low air pressure and volume transmitters, PID controllers and have one volt free change over alarm relay and a buzzer on board. They are for use in laboratory, clean room installations containment facilities and commercial and industrial ventilation systems.They have overload protection and auto-zero.
The Transmitters have a linear output to pressure or air volume. They work with all CMR duct mounted Veloprobes, Flowprobes, Flowgrids and Venturis. One red and one green led can indicate high or low alarm on the keypad front panel. Signal outputs of 0..10V and 4..20mA as well as modbus rtu is fitted for connection to the BMS, SCADA or PLC’s. There is an additional modbus rtu connection to operate a variety of remote alarm display panels.
Power supplies 24Vdc, 24Vac, 110Vac and 230Vac are available. CE conformity certificates as well as calibration certificates traceable to International Standards (UKAS) are supplied. as standard. All commissioning configurations can be done via the standard operator’s keyboard.
- Ultra low pressure and volume measurement
- Traceable Calibration Certificate is included
- High accuracy and repeatability
- Linear pressure or air volume output
- Both measurement and PID control output
- Two modbus for monitoring and remote display
- One alarm relay, buzzer and LED indicators
- Auto Zero and overload protection is standard
- Operator keyboard display for all functions
- Two Modbus rtu, 0..10V and 4..20mA outputs
- IP65 enclosure with easy mount wall bracket
- 24 month warranty
- 30 Years field application experience
- Technical specification
-
V-Sensor
Measurement Range Any Range from 0-25Pa or -/+25Pa up to 0-7500Pa or -/+7500Pa Overload Capacity Ranges 25Pa – 150Pa up to max 1200Pa if over pressure protection is off.
Ranges from 200Pa – 7500Pa up to max 10 times of range if over pressure protection is off.Media Non corrosive gases such as Air, N2, O2, Co2, N2O and inert gases Diaphragm Unit Beryllium Copper suitable for high concentration of Formaldehyde – Stainless Steel on request. AC Power Supplies
Transformer Isolated24 Vac 50/60Hz 198mA. Internal Fuse 300mA Auto-Reset
110Vac 50/60Hz 40mA. Fuse 315mA Wickmann.
230Vac 50/60Hz 20mA. Fuse 315mA WickmannDC Power Supplies 24 Vdc (19 to 31Vdc) smoothed 118mA Internal Fuse 300mA Auto-Reset. Voltage Output Signal 0-10V (0 to100% of Range) RL = 5kOhm min.Other output signals (e.g. 2-10V) or PID loop control is programmable via the keyboard. Current Output Signal
Relay Output 1A 24Vdc4-20mA (0 to100% of Range) RL = 500 Ohm max (0-20mA) or PID control is programmable via keyboardOne Alarm changer over volt free contact is user programmable 2 x Modbus rtu Connection 2 x Output Signal, Alarm Status, Alarm Thresholds and Alarm Timers are all readable as Modbus rtuCommands. Modbus register assignments to read and write are available in user manual. Hysteresis/Repeatability 0.1% Typical of Full Scale. Linearity (Accuracy) +/- 0.25% of Full scale = > 100 Pa and 0.25Pa < 100Pa. Zero Drift 0.05%K (+10°C to +50°C) – Automatically corrected to 0.0 if Auto-Zero function is enabled Operating Temperature -10°C to +70°C. Mounting Position Vertical. Weight 0.6 kg in ABS Housing. Electrical Connections ABS Housing: 1 x M20 Gland and 1 x M12 Gland and internal removable Screw Terminals.