TP M255S
Sika Micro calibration bath RT to 255°C
The use of calibration liquids offers certain advantages if temperature sensors with an unusual shape and size are to be tested. The test item is immersed directly into the liquid without an insulating air gap, resulting in direct temperature contact between the calibrator and the test item. The liquid, such as silicone oil, is chosen depending on the calibration temperature required. The continuous adjustment of the magnetic stirrer together with the removable sensor basket agitates the calibration liquid to create a large measuring zone. Furthermore, the sensor basket guarantees unhindered stirring and helps protect the tank floor.
Applications
Assembly and commissioning – Manufacturing and production – Maintenance and service – Quality assurance and test equipment monitoring – Repair
TP M 255 S
Temperature range* | RT…255 °C |
Tolerance | ±0.2 °C |
Stability | ±0.05 °C |
Dryblock | |
Temperature range | RT…255 °C |
Tolerance | ±0.4 °C |
Stability | ±0.05 °C |
Infrared | |
Temperature range | RT…255 °C |
Tolerance | ±0.5 °C |
Stability | ±0.05 °C |
Resolution | 0.01 °C in the range of RT…99.99 °C, else 0.1 °C |
Block | Ø 60 mm / depth 170 mm |
Display | 2-line, 4-digit display Red / green, unit °C (°F optional) |
Display range | 0…225 °C |
Resolution | 0.01 °C in the range of RT…99.99 °C, else 0.1 °C |
General data | |
Dimensions
– Width |
150 mm 330 + 70 mm 270 mm |
Weight | Approx. 7.5 kg |
Power supply | 230 VAC, ±10 %, 50 / 60 Hz, optional 115 VAC, ±10 %, 50 / 60 Hz |
Power consumption | Approx. 1000 VA |
- Overview
-
TP M255S
Sika Micro calibration bath RT to 255°C
The use of calibration liquids offers certain advantages if temperature sensors with an unusual shape and size are to be tested. The test item is immersed directly into the liquid without an insulating air gap, resulting in direct temperature contact between the calibrator and the test item. The liquid, such as silicone oil, is chosen depending on the calibration temperature required. The continuous adjustment of the magnetic stirrer together with the removable sensor basket agitates the calibration liquid to create a large measuring zone. Furthermore, the sensor basket guarantees unhindered stirring and helps protect the tank floor.
Applications
Assembly and commissioning – Manufacturing and production – Maintenance and service – Quality assurance and test equipment monitoring – Repair
- Technical Specifications
-
TP M 255 S
Temperature range* RT…255 °C Tolerance ±0.2 °C Stability ±0.05 °C Dryblock Temperature range RT…255 °C Tolerance ±0.4 °C Stability ±0.05 °C Infrared Temperature range RT…255 °C Tolerance ±0.5 °C Stability ±0.05 °C Resolution 0.01 °C in the range of RT…99.99 °C,
else 0.1 °CBlock Ø 60 mm / depth 170 mm Display 2-line, 4-digit display
Red / green, unit °C (°F optional)Display range 0…225 °C Resolution 0.01 °C in the range of RT…99.99 °C,
else 0.1 °CGeneral data Dimensions – Width
– Height
– Depth150 mm
330 + 70 mm
270 mmWeight Approx. 7.5 kg Power supply 230 VAC, ±10 %, 50 / 60 Hz,
optional 115 VAC, ±10 %, 50 / 60 HzPower consumption Approx. 1000 VA - Downloads