Sika TP M 165 S
Temperature calibrator Micro bath function
SIKA temperature calibrators can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. They cover a broad spectrum of industries with diverse applications.
Micro bath function
The use of calibration liquids offers certain advantages if temperature sensors with an unusual shape and size are to be tested. The test item is immersed directly into the liquid without an insulating air gap, resulting in direct temperature contact between the calibrator and the test item. The liquid, such as silicone oil, is chosen depending on the calibration temperature required. The continuous adjustment of the magnetic stirrer together with the removable sensor basket agitates the calibration liquid to create a large measuring zone. Furthermore, the sensor basket guarantees unhindered stirring and helps protect the tank floor.
Applications
Assembly and commissioning – Manufacturing and production – Maintenance and service – Quality assurance and test equipment monitoring – Repair
TP M 165 S |
|
Temperature Range* | -35°C to 165 °C |
Tolerance | ±0,1 °C |
Stability | ±0,05 °C |
Resolution | 0,01 °C in the range of -9,99°C to 99,99 °C, else 0,1 °C |
Block | Ø 60 mm / depth 170 mm |
* At an ambient temperature of 20 °C
- Overview
-
Sika TP M 165 S
Temperature calibrator Micro bath function
SIKA temperature calibrators can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. They cover a broad spectrum of industries with diverse applications.
Micro bath function
The use of calibration liquids offers certain advantages if temperature sensors with an unusual shape and size are to be tested. The test item is immersed directly into the liquid without an insulating air gap, resulting in direct temperature contact between the calibrator and the test item. The liquid, such as silicone oil, is chosen depending on the calibration temperature required. The continuous adjustment of the magnetic stirrer together with the removable sensor basket agitates the calibration liquid to create a large measuring zone. Furthermore, the sensor basket guarantees unhindered stirring and helps protect the tank floor.Applications
Assembly and commissioning – Manufacturing and production – Maintenance and service – Quality assurance and test equipment monitoring – Repair
- Technical Specifications
-
TP M 165 S
Temperature Range* -35°C to 165 °C Tolerance ±0,1 °C Stability ±0,05 °C Resolution 0,01 °C in the range of -9,99°C to 99,99 °C, else 0,1 °C Block Ø 60 mm / depth 170 mm * At an ambient temperature of 20 °C
- Downloads