TP 17 450

SIKA temperature calibrators can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. They cover a broad spectrum of industries with diverse applications.

Dry block function
The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and diameter can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flash points or outgassing are of no concern.

  • Assembly and commissioning
  • Manufacturing and production
  • Maintenance and service
  • Quality assurance and test equipment monitoring
  • Repair

 

Applications

Pharmacies – Products / Meat / Dairy – Chemicals – Laboratories – Assembly and commissioning – Production and production – Maintenance and service – Quality assurance and monitoring of test equipment – Repair

 

TP 17 450

 

Temperature range RT …450°C
Tolerance ±0,6°C
Stability ±0,1°C
Résolution 0,1 °C
Block Ø 60 mm / depth 150 mm

* At an ambient temperature of 20 °C

Overview

TP 17 450

SIKA temperature calibrators can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. They cover a broad spectrum of industries with diverse applications.

Dry block function
The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and diameter can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flash points or outgassing are of no concern.

  • Assembly and commissioning
  • Manufacturing and production
  • Maintenance and service
  • Quality assurance and test equipment monitoring
  • Repair

 

Applications

Pharmacies – Products / Meat / Dairy – Chemicals – Laboratories – Assembly and commissioning – Production and production – Maintenance and service – Quality assurance and monitoring of test equipment – Repair

 

Technical specification

TP 17 450

 

Temperature range RT …450°C
Tolerance ±0,6°C
Stability ±0,1°C
Résolution 0,1 °C
Block Ø 60 mm / depth 150 mm

* At an ambient temperature of 20 °C

Download