Testo 6740 : Dew point transmitter

 

The testo 6740 was especilally developed for trace humidity measurement in compressed or dry air (e. g. granulate dryers). Thanks to a special adjustment, optimum accuracy in the trace humidity range has been achieved. For the display of the relevant trace humidity parameters, a freely scalable analog output is available, optionally with a switch contact plug for MAX monitoring. In addition to this, the testo 6740 stands out thanks to its compact and user-friendly design, such as the rotatability of the housing by 350° for the optimum positioning of the display.

 

  • Measurement of dewpoints in the range from-45 °Ctd to +30 °Ctd
  • Testo polymer humidity sensor with high accuracy and long-term stability
  • Analog output 4 to 20 mA (2-wire) and optional alarm plug with 2 integrated switch outputs
  • Compact design with rotatable housing by 350° for optimum positioning of display
  • Display with operating menu (optional)

Testo 6740 Dew point transmitter

Dewpoint/trace humidity
Units %RH, °C
Calculated parameters °Ctd, °Ftd, °CtA, °FtA, ppmv, mg/m3, °F
Measuring range -45 °Ctd to +30 °Ctd
Measurement uncertainty ±1 K at 0 °Ctd (+32 °Ftd)
±3 K at -20 °Ctd (-4 °Ftd)
±4 K at -40 °Ctd (-40 °Ftd)
Sensor Polymer humidity sensor with protocolized trace humidity adjustment at -40 °Ctd (-40 °Ftd)
Normed atmospheric dewpoint
Measuring range -70 to -15 °CtdA (-112 to -5 °FtdA) (at 30 bar rel./ 435 psi)
-54 to +10 °CtdA (-94 to +50 °FtdA) (at 3 bar rel./43.5 psi)
-45 to +30° CtdA (-76 to +86 °FtdA) (at 0 bar rel./0 psi)
Temperature
Measuring range 0 to 50 °C (32 to +122 °F)
Measurement uncertainty ±0,5K (0 to 50 °C/32 to 122 °F)
Sensor NTC
Analog outputs
Current/accuracy 4 to 20 mA (2-wire) / ±40 μA
Measurement rate 2 s
Resolution 12 bit
load 12 V DC: max. 100 Ω, 24 V DC: max. 650 Ω,30 V DC: 950 Ω
Scaling Freely scalable via display buttons
Switch outputs (opt. alarm plug, 0554 3302)
Contacts 2 closer contacts, pot.-free, max. 30V/0.5A
Switch thresholds Standard 6 °Ctd/12 °Ctd, freely programmable with display
Supply
Voltage supply 24 V DC (12 to 30 V DC permitted);
with alarm plug (0554 3302) 20 to 28 V DC
Current consumption 21 mA (without alarm plug)
65 mA (with alarm plug)
Overview

Testo 6740 : Dew point transmitter

 

The testo 6740 was especilally developed for trace humidity measurement in compressed or dry air (e. g. granulate dryers). Thanks to a special adjustment, optimum accuracy in the trace humidity range has been achieved. For the display of the relevant trace humidity parameters, a freely scalable analog output is available, optionally with a switch contact plug for MAX monitoring. In addition to this, the testo 6740 stands out thanks to its compact and user-friendly design, such as the rotatability of the housing by 350° for the optimum positioning of the display.

 

  • Measurement of dewpoints in the range from-45 °Ctd to +30 °Ctd
  • Testo polymer humidity sensor with high accuracy and long-term stability
  • Analog output 4 to 20 mA (2-wire) and optional alarm plug with 2 integrated switch outputs
  • Compact design with rotatable housing by 350° for optimum positioning of display
  • Display with operating menu (optional)
Technical specification

Testo 6740 Dew point transmitter

Dewpoint/trace humidity
Units %RH, °C
Calculated parameters °Ctd, °Ftd, °CtA, °FtA, ppmv, mg/m3, °F
Measuring range -45 °Ctd to +30 °Ctd
Measurement uncertainty ±1 K at 0 °Ctd (+32 °Ftd)
±3 K at -20 °Ctd (-4 °Ftd)
±4 K at -40 °Ctd (-40 °Ftd)
Sensor Polymer humidity sensor with protocolized trace humidity adjustment at -40 °Ctd (-40 °Ftd)
Normed atmospheric dewpoint
Measuring range -70 to -15 °CtdA (-112 to -5 °FtdA) (at 30 bar rel./ 435 psi)
-54 to +10 °CtdA (-94 to +50 °FtdA) (at 3 bar rel./43.5 psi)
-45 to +30° CtdA (-76 to +86 °FtdA) (at 0 bar rel./0 psi)
Temperature
Measuring range 0 to 50 °C (32 to +122 °F)
Measurement uncertainty ±0,5K (0 to 50 °C/32 to 122 °F)
Sensor NTC
Analog outputs
Current/accuracy 4 to 20 mA (2-wire) / ±40 μA
Measurement rate 2 s
Resolution 12 bit
load 12 V DC: max. 100 Ω, 24 V DC: max. 650 Ω,30 V DC: 950 Ω
Scaling Freely scalable via display buttons
Switch outputs (opt. alarm plug, 0554 3302)
Contacts 2 closer contacts, pot.-free, max. 30V/0.5A
Switch thresholds Standard 6 °Ctd/12 °Ctd, freely programmable with display
Supply
Voltage supply 24 V DC (12 to 30 V DC permitted);
with alarm plug (0554 3302) 20 to 28 V DC
Current consumption 21 mA (without alarm plug)
65 mA (with alarm plug)