The differential pressure transmitter testo 6381 was developed specially for monitoring differential pressure in the measuring range from 10 Pa to 1000 hPa. In cleanroom technology, the maintenance of positive pressure prevents the entry of contaminated air. In addition to this, the flow velocity or the volume flow can be calculated from the measurement of the differential pressure in a Pitot tube. Thanks to an optional probe from the probe series 6610, the additional recording of humidity and temperature with one instrument is also possible.The testo 6381 is particularly outstanding thanks to the automatioc zero-point adjustment which ensures high accuracy and long-term stability.The integrated self-monitoring and early warning function also guarantees the operator high system availability.

 

  • Automatic zero-point adjustment guarantees high temperature-independent accuracy and long-term stability
  • Low measuring range from 10 Pa ensures very high precision at the lowest pressures
  • Pressure transmitter for differential pressure, flow velocity and volume flow, as an option: humidity and temperature
  • Configurable alarm management with adjustable response delay and alarm acknowledgement

 

TESTO 6381

differential pressure transmitter with flow calculation

 

differential pressure


Measuring range 0 … 10 Pa
0 … 50 Pa
0 … 100 Pa
0 … 500 Pa
0 … 10 hPa
0 … 50 hPa
0 … 100 hPa
0 … 500 hPa
0 … 1000 hPa
-10 … 10 Pa
-50 … 50 Pa
-100 … 100 Pa
-500 … 500 Pa
-10 … 10 hPa
-50 … 50 hPa
-100 … 100 hPa
-500 … 500 hPa
-1000 … 1000 hPa
Measurement uncertainty* ±0.5% of measurement range final value
±0.3 Pa
Temperature gain drift: 0.03% of measuring range per Kelvin deviaton from nominal temperature 22°C
Zero-point: 0% (thanks to cyclic zero-point adjustment)
Sensor Piezoresistive sensor
Autom. zero-point adjustment via magnetic valveFrequency adjustable: 15 sec, 30 sec, 1 min, 5 min, 10 min
Overload capacity Measuring range
0 to 10 Pa
0 to 50 Pa
0 to 100 Pa
0 to 500 Pa
0 to 10 hPa
0 to 50 hPa
0 to 100 hPa
0 to 500 hPa
0 to 1000 hPa
10 … 10 Pa
-50 to 50 Pa
-100 to 100 Pa
-500 to 500 Pa
-10 to 10 hPa
-50 to 50 hPa
-100 to 100 hPa
-500 to 500 hPa
-1000 to 1000 hPa
Overload
20000 Pa
20000 Pa
20000 Pa
20000 Pa
200 hPa
750 hPa
750 hPa
2500 hPa
2500 hPa
20000 Pa
20000 Pa
20000 Pa
20000 Pa
200 hPa
750 hPa
750 hPa
2500 hPa
2500 hPa
Inputs and outputs
Analog outputs
Output type 0/4 to 20 mA (4-wire) (24 VAC/DC)
0 to 1/5/10 V (4-wire) (24 VAC/DC)
Measuring rate 1/s
Resolution 12 bit
Max. load 500 Ω
Scaling Differential pressure: scalable ±50% of measuring range final value;freely scalable within measuring range
Voltage supply 20 to 30 VAC/DC, 300 mA current consumption, galvanically separate signal and supply line
Overview

Testo 6381 : Transmetteur de pression différentielle avec option humidité/température

 

The differential pressure transmitter testo 6381 was developed specially for monitoring differential pressure in the measuring range from 10 Pa to 1000 hPa. In cleanroom technology, the maintenance of positive pressure prevents the entry of contaminated air. In addition to this, the flow velocity or the volume flow can be calculated from the measurement of the differential pressure in a Pitot tube. Thanks to an optional probe from the probe series 6610, the additional recording of humidity and temperature with one instrument is also possible.The testo 6381 is particularly outstanding thanks to the automatioc zero-point adjustment which ensures high accuracy and long-term stability.The integrated self-monitoring and early warning function also guarantees the operator high system availability.

 

  • Automatic zero-point adjustment guarantees high temperature-independent accuracy and long-term stability
  • Low measuring range from 10 Pa ensures very high precision at the lowest pressures
  • Pressure transmitter for differential pressure, flow velocity and volume flow, as an option: humidity and temperature
  • Configurable alarm management with adjustable response delay and alarm acknowledgement

 

Technical specification

TESTO 6381

differential pressure transmitter with flow calculation

 

differential pressure


Measuring range 0 … 10 Pa
0 … 50 Pa
0 … 100 Pa
0 … 500 Pa
0 … 10 hPa
0 … 50 hPa
0 … 100 hPa
0 … 500 hPa
0 … 1000 hPa
-10 … 10 Pa
-50 … 50 Pa
-100 … 100 Pa
-500 … 500 Pa
-10 … 10 hPa
-50 … 50 hPa
-100 … 100 hPa
-500 … 500 hPa
-1000 … 1000 hPa
Measurement uncertainty* ±0.5% of measurement range final value
±0.3 Pa
Temperature gain drift: 0.03% of measuring range per Kelvin deviaton from nominal temperature 22°C
Zero-point: 0% (thanks to cyclic zero-point adjustment)
Sensor Piezoresistive sensor
Autom. zero-point adjustment via magnetic valveFrequency adjustable: 15 sec, 30 sec, 1 min, 5 min, 10 min
Overload capacity Measuring range
0 to 10 Pa
0 to 50 Pa
0 to 100 Pa
0 to 500 Pa
0 to 10 hPa
0 to 50 hPa
0 to 100 hPa
0 to 500 hPa
0 to 1000 hPa
10 … 10 Pa
-50 to 50 Pa
-100 to 100 Pa
-500 to 500 Pa
-10 to 10 hPa
-50 to 50 hPa
-100 to 100 hPa
-500 to 500 hPa
-1000 to 1000 hPa
Overload
20000 Pa
20000 Pa
20000 Pa
20000 Pa
200 hPa
750 hPa
750 hPa
2500 hPa
2500 hPa
20000 Pa
20000 Pa
20000 Pa
20000 Pa
200 hPa
750 hPa
750 hPa
2500 hPa
2500 hPa
Inputs and outputs
Analog outputs
Output type 0/4 to 20 mA (4-wire) (24 VAC/DC)
0 to 1/5/10 V (4-wire) (24 VAC/DC)
Measuring rate 1/s
Resolution 12 bit
Max. load 500 Ω
Scaling Differential pressure: scalable ±50% of measuring range final value;freely scalable within measuring range
Voltage supply 20 to 30 VAC/DC, 300 mA current consumption, galvanically separate signal and supply line