EMTEK R100

REMOTE AIR SAMPLER CONTROLLER

 

EMTEK’s NEW R100 Remote Microbial Sampling System is intended for process monitoring of your critical ISO 5 Zones (eg, Isolators, LAF Hoods, BSC’s, BFS Chambers, Filling Lines, etc.), by remotely operating EMTEK’s Remote Air Samplers (RAS) placed at key locations within those critical areas, through either flexible, or fixed rigid vacuum tubing.

The R100 is designed to operate both 28.3 and 100 LPM P100 Remote Air Samplers, with 28.3 LPM sampling possible through 0.375″ or 0.500″ ID tubing at up to 50 Feet (15 Meters), and 100 LPM sampling at 10 Feet (3M).

As the R100 generally intended for fixed locations, the R100 does require direct AC power for it’s AC/DC power supply.  Although, battery operation will also be an option for the R100.

The R100 will include our PC Control Software, as well as the R100 Firmware MODBUS Map set, as customers may want to use the MODBUS Maps to create drivers to integrate the R100 with their FMS systems.  Our 5 Channel IR Remote will be included with the R100 Packages as well.

Sample Time/Volume Variable (User Defined), Maximums: 120-minutes/3396 Liters* @ 28.3 LPM, 30-min/3000L @ 100 LPM
Delay/Hold Times Variable (User Defined)
Sample Flow Rates 28.3 LPM (1 CFM), or 100 LPM (Requires separate inlet covers for the 28.3 & 100 LPM Sample Rates)
Flow Rate Control Electronic, Closed-Loop, Mass-Flow Control
Printer (Optional) Thermal Label or Paper
Control System (CPU) Microprocessor Controlled (32bit PIC Processor)
Memory 512kb Flash Program, 128kb RAM Data, 1mb Sample Runs, 512kb EPROM Calibration Set Points
Unit Equipment ID/Number User Defined/Selectable
Site Descriptions User Created/Deleted/Selectable
Program Descriptions User Created/Deleted/Selectable (Includes: Sample Rate, Volume/Time, Flow/Volume Units, Delay/Test/Hold)
Sample ID Unique System Generated (Unit Serial # + 5 digit string) / Non-Repeating until >999,999 samples
Input/Output USB Client 1.1, Ethernet 10BaseT-/100-BaseT
Audible Alarm Internal (with User Volume Control)
Alarms Flow Alarm +5% (On/Off)
AC/DC Power Supply OPERATION REQUIRES AC POWER Input: 100-240 VAC, 50/60 Hz,130VA-168VA 1.4 AMPS / Output: DC 18V 3.6A
Operating Range 5-40º C, 10-80% RH, non-condensing*; Indoor Use; Max Altitude 6560 feet (2000 meters)
*Note: As temperature increases from 30 to 40º C, humidity range drops from 80 to 50% linearly.
Operational Tubing Length Maximum Tubing Length at 28.3LPM Cannot Exceed 50 Feet (15 Meters) / 0.375” or 0.500” ID
Maximum Tubing Length at 100LPM Cannot Exceed 10 Feet (3 Meters) / 0.500” ID
Calibration/Verification Required Flow Rate (28.3/1 CFM and/or 100 LPM) / Sample Timer (Frequency: 6-12 Months)
Installation Category/Pollution Degree Category 1 / 1 & 2
Enclosure 316SS
Dimensions LxWxH 20 x 9.2 x 9.5 cm
Weight 1.7 kg
Overview

EMTEK R100

REMOTE AIR SAMPLER CONTROLLER

 

EMTEK’s NEW R100 Remote Microbial Sampling System is intended for process monitoring of your critical ISO 5 Zones (eg, Isolators, LAF Hoods, BSC’s, BFS Chambers, Filling Lines, etc.), by remotely operating EMTEK’s Remote Air Samplers (RAS) placed at key locations within those critical areas, through either flexible, or fixed rigid vacuum tubing.

The R100 is designed to operate both 28.3 and 100 LPM P100 Remote Air Samplers, with 28.3 LPM sampling possible through 0.375″ or 0.500″ ID tubing at up to 50 Feet (15 Meters), and 100 LPM sampling at 10 Feet (3M).

As the R100 generally intended for fixed locations, the R100 does require direct AC power for it’s AC/DC power supply.  Although, battery operation will also be an option for the R100.

The R100 will include our PC Control Software, as well as the R100 Firmware MODBUS Map set, as customers may want to use the MODBUS Maps to create drivers to integrate the R100 with their FMS systems.  Our 5 Channel IR Remote will be included with the R100 Packages as well.

Technical Specifications
Sample Time/Volume Variable (User Defined), Maximums: 120-minutes/3396 Liters* @ 28.3 LPM, 30-min/3000L @ 100 LPM
Delay/Hold Times Variable (User Defined)
Sample Flow Rates 28.3 LPM (1 CFM), or 100 LPM (Requires separate inlet covers for the 28.3 & 100 LPM Sample Rates)
Flow Rate Control Electronic, Closed-Loop, Mass-Flow Control
Printer (Optional) Thermal Label or Paper
Control System (CPU) Microprocessor Controlled (32bit PIC Processor)
Memory 512kb Flash Program, 128kb RAM Data, 1mb Sample Runs, 512kb EPROM Calibration Set Points
Unit Equipment ID/Number User Defined/Selectable
Site Descriptions User Created/Deleted/Selectable
Program Descriptions User Created/Deleted/Selectable (Includes: Sample Rate, Volume/Time, Flow/Volume Units, Delay/Test/Hold)
Sample ID Unique System Generated (Unit Serial # + 5 digit string) / Non-Repeating until >999,999 samples
Input/Output USB Client 1.1, Ethernet 10BaseT-/100-BaseT
Audible Alarm Internal (with User Volume Control)
Alarms Flow Alarm +5% (On/Off)
AC/DC Power Supply OPERATION REQUIRES AC POWER Input: 100-240 VAC, 50/60 Hz,130VA-168VA 1.4 AMPS / Output: DC 18V 3.6A
Operating Range 5-40º C, 10-80% RH, non-condensing*; Indoor Use; Max Altitude 6560 feet (2000 meters)
*Note: As temperature increases from 30 to 40º C, humidity range drops from 80 to 50% linearly.
Operational Tubing Length Maximum Tubing Length at 28.3LPM Cannot Exceed 50 Feet (15 Meters) / 0.375” or 0.500” ID
Maximum Tubing Length at 100LPM Cannot Exceed 10 Feet (3 Meters) / 0.500” ID
Calibration/Verification Required Flow Rate (28.3/1 CFM and/or 100 LPM) / Sample Timer (Frequency: 6-12 Months)
Installation Category/Pollution Degree Category 1 / 1 & 2
Enclosure 316SS
Dimensions LxWxH 20 x 9.2 x 9.5 cm
Weight 1.7 kg