MET ONE 6000
Remote Airborn Particle Counters
The Met One 6000 series remote airborne particle counter offers accurate and reliable continuous particle monitoring. With a sensitivity range of 0.3 or 0.5 to 10 μm, data accuracy and repeatability through ISO 21501 compliant calibration, the Met One 6000 series is designed to meet the specific needs of cleanroom operations within the pharmaceutical, semiconductor, hard disk drive and flat panel display industries.
Built with Long Life Laser™ technology, the MET ONE 6000 offers industry leading diagnostic features that reduce troubleshooting time and related downtime costs.
Product Highlights
- Easy to integrate with any FMS system
- Sensitivity range of 0.3, 0.5, 10 μm
- Long Life Laser diode
- resistant VHP (hydrogen peroxide)
- Pulse, Modbus, Ethernet, wifi and analog modes
Applications
HVAC, Laboratory Control, Industrial Hygiene Quality Control, Pharmaceutical Industry,
MET ONE 6000
|
Remote Airborn Particle Counters
|
Light source | Long Life Laser™ diode |
weight | 0.82 kg (1.8 lbs) |
Dimensions | 13.56 w x 8.93 d x 12.06 h cm (5.34 x 3.52 x 4.75 inches) |
Enclosure | 304 stainless steel |
Status Indicator
|
Multi-coloured LED for normal status, count alarm, count alert, sensor failure, flow failure or communication failure |
Power Requirements | 9 to 28 VDC |
Power Consumption
|
Serial and pulse units: 3.3 W; Ethernet unit: 4.3 W; Analog: 3.5 W;
Wireless: 7.1 W. Maximum amperage requirement: 1 A |
Operating Temperature | 10 to 32 °C (50 to 90 °F), 5 to 95% relative humidity, non-condensing |
Storage Temperature | -40 to 70 °C (-40 to 158 °F), 5 to 98% relative humidity, non-condensing |
Signal Output Options
|
Pulse Analog 4–20 mA Serial RS-232 Serial RS-485 with Modbus RTU or FXB communication protocol Ethernet or Wireless with TCP/IP protocol |
Vacuum Requirements | At least 40.6 cm (16 inches) Hg |
Number of Size Channels | Standard 2 or Optional 4 (pulse units have 2 channels only) |
Flow Control | Through critical orifice |
Coincidence Loss
|
Model 6003/6005: 5% at 2,000,000 particles/ft3 (70,600,000 particles/m3) |
Model 6013/6015: 5% at 400, 000 particle/ft3
(except Pulse) (14,000,000 particles/m3)False Count RateOne or less in five minutesAccessories IncludedDIN Rail Mounting Kit, Isokinetic Probe,
Male Phoenix Terminal Strip with Cover, Operator Manual
- Overview
-
MET ONE 6000
Remote Airborn Particle Counters
The Met One 6000 series remote airborne particle counter offers accurate and reliable continuous particle monitoring. With a sensitivity range of 0.3 or 0.5 to 10 μm, data accuracy and repeatability through ISO 21501 compliant calibration, the Met One 6000 series is designed to meet the specific needs of cleanroom operations within the pharmaceutical, semiconductor, hard disk drive and flat panel display industries.
Built with Long Life Laser™ technology, the MET ONE 6000 offers industry leading diagnostic features that reduce troubleshooting time and related downtime costs.
Product Highlights
- Easy to integrate with any FMS system
- Sensitivity range of 0.3, 0.5, 10 μm
- Long Life Laser diode
- resistant VHP (hydrogen peroxide)
- Pulse, Modbus, Ethernet, wifi and analog modes
Applications
HVAC, Laboratory Control, Industrial Hygiene Quality Control, Pharmaceutical Industry,
- Technical Specifications
-
MET ONE 6000
Remote Airborn Particle Counters
Light source Long Life Laser™ diode weight 0.82 kg (1.8 lbs) Dimensions 13.56 w x 8.93 d x 12.06 h cm (5.34 x 3.52 x 4.75 inches) Enclosure 304 stainless steel Status Indicator Multi-coloured LED for normal status, count alarm, count alert,
sensor failure, flow failure or communication failurePower Requirements 9 to 28 VDC Power Consumption Serial and pulse units: 3.3 W; Ethernet unit: 4.3 W; Analog: 3.5 W; Wireless: 7.1 W. Maximum amperage requirement: 1 A
Operating Temperature 10 to 32 °C (50 to 90 °F), 5 to 95% relative humidity, non-condensing Storage Temperature -40 to 70 °C (-40 to 158 °F), 5 to 98% relative humidity, non-condensing Signal Output Options Pulse
Analog 4–20 mA
Serial RS-232
Serial RS-485 with Modbus RTU or FXB communication protocol
Ethernet or Wireless with TCP/IP protocolVacuum Requirements At least 40.6 cm (16 inches) Hg Number of Size Channels Standard 2 or Optional 4 (pulse units have 2 channels only) Flow Control Through critical orifice Coincidence Loss Model 6003/6005: 5% at 2,000,000 particles/ft3
(70,600,000 particles/m3)Model 6013/6015: 5% at 400, 000 particle/ft3
(except Pulse) (14,000,000 particles/m3)False Count RateOne or less in five minutesAccessories IncludedDIN Rail Mounting Kit, Isokinetic Probe,
Male Phoenix Terminal Strip with Cover, Operator Manual - Downloads