MET ONE 3400+ particle counter
Automate environmental monitoring for GMP cleanroom compliance with ONE easy decision
The MET ONE 3400+ Series Portable Airborne Particle Counter features automated integrated electronic SOPs and sampling maps that reduce training requirements—and sampling errors. Using a web-browser interface, load your SOP map into the counter, mark sample locations, and define SOP requirements for each.
The MET ONE 3400+ helps you manage accurate cleanroom monitoring data via safe and secure internal software and web access—there’s no external software needed. All data is encrypted, and users are never permitted to delete records.
And because it uses Microsoft Active Directory for Username and Password Control for log-on and electronic signatures, it supports 21 CFR Part 11 compliance and ALCOA guidance.
We live in an interconnected world, but for many GMP regulated devices to share data requires huge software integrations and validation. The MET ONE 3400+ has built-in, secure networking capabilities that are validated out of the box using our IQ / OQ protocols. A lightweight networking protocol securely protected via transport layer security (TLS) in the MET ONE 3400+ interconnects multiple devices and shares configuration and sample data in a secure and compliant manner. Ease the burden on your IT department with the new MET ONE 3400+ air particle counter.
- Customized Electronic SOP Maps
- Interactive Tracking
- Automated SOP Version Control
- Review and Approve
- Secure Electronic Records
- Barcode Function (optional)
- Plug-n-Play Networking
- Sampling Options
Applications
Cleanroom environmental monitoring – Aseptic pharmaceutical production – Continuous environmental monitoring – Process troubleshooting – HEPA filter leak detection – Hygiene Quality Control – Laboratory – Micro-electronic Industry
models | MET ONE 3413+ | MET ONE 3415+ / | MET ONE 3423+ | METONE 3425+ | MET ONE 3445+ |
Standard Sizes | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm |
0.5, 1.0, 2.0, 3.0, 5.0, 10.0 μm |
0.5, 1.0, 2.0, 3.0, 5.0, 10.0 μm |
0.5, 1.0, 2.0, 3.0, 5.0, 10.0 μm |
0.5, 1.0, 2.0, 3.0, 5.0, 10.0 μm |
Flow Rate | 28.3 LPM (1.0 CFM) | 28.3 LPM (1.0 CFM) | 50 LPM (1.77 CFM) | 50 LPM (1.77 CFM) | 100 LPM (3.53 CFM) |
Flow Rate Tolerance | ±5% | ±5% | ±5% | ±5% | ±5% |
Time to sample 1 m³ | 35.3 minutes | 35.3 minutes | 20 minutes | 20 minutes | 10 minutes |
Zero Count | 1 count or less in 5 minutes, 95% confidence level |
1 count or less in 5 minutes, 95% confidence level |
1 count or less in 5 minutes, 95% confidence level |
1 count or less in 5 minutes, 95% confidence level |
1 count or less in 5 minutes, 95% confidence level |
Coincidence Loss | 10% at 36,000,000 particles per m³ |
10% at 36,000,000 particles per m³ |
10% at 20,000,000 particles per m³ |
10% at 20,000,000 particles per m³ |
10% at 10,000,000 particles per m³ |
Counting Efficiency – 50% | 50% ±20% for 0.3 μm | 50% ±20% for 0.5 μm | 50% ±20% for 0.3 μm | 50% ±20% for 0.5 μm | 50% ±20% for 0.5 μm |
Counting Efficiency – 100% | 100% ±10% for 0.45 μm |
100% ±10% for 0.75 μm |
100% ±10% for 0.45 μm |
100% ±10% for 0.75 μm |
100% ±10% for 0.75 μm |
Light Source | Long Life Laser™ diode with 10-year Mean Time To Failure |
Long Life Laser™ diode with 10-year Mean Time To Failure |
Long Life Laser™ diode with 10-year Mean Time To Failure |
Long Life Laser™ diode with 10-year Mean Time To Failure |
Long Life Laser™ diode with 10-year Mean Time To Failure |
Pump Type | Filtered to ISO 3 specifications, 3/8” NPT pipe fitting | Filtered to ISO 3 specifications, 3/8” NPT pipe fitting | Filtered to ISO 3 specifications, 3/8” NPT pipe fitting | Filtered to ISO 3 specifications, 3/8” NPT pipe fitting | Filtered to ISO 3 specifications, 3/8” NPT pipe fitting |
Exhaust | 3/8″ NPT pipe fitting available | 3/8″ NPT pipe fitting available | 3/8″ NPT pipe fitting available | 3/8″ NPT pipe fitting available | 3/8″ NPT pipe fitting available |
AC Power Supply | Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum | Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum | Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum | Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum | Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum |
Battery Type and Quantity | 1, 2 or 3 Li Ion Rechargeable Smart Battery Packs | 1, 2 or 3 Li Ion Rechargeable Smart Battery Packs | 1, 2 or 3 Li Ion Rechargeable Smart Battery Packs | 1, 2 or 3 Li Ion Rechargeable Smart Battery Packs | 3 Li Ion Rechargeable Smart Battery Packs |
Battery Life (Continuous Sampling) w/ 1 Battery | 3 hours | 3 hours | 3 hours | 3 hours | Pump will not operate |
Battery Life (Continuous Sampling) w/ 2 Battery | 6.25 hours | 6.25 hours | 6.5 hours | 6.5 hours | 4 hours |
Battery Life (Continuous Sampling) w/ 2 Battery | 9.25 hours | 9.25 hours | 9.75 hours | 9.75 hours | 5.5 hours |
Maximum Battery Recharge Time | 3.5 hours (with 2 batteries) | 3.5 hours (with 2 batteries) | 3.5 hours (with 2 batteries) | 3.5 hours (with 2 batteries) | 6.75 hours (with 3 batteries) |
Dimensions (cm) | 26.7 W x 26 H x 21 D |
Weight (without battery) | 5.6 kg (12.4 lbs) |
Weight (with included batteries) | 6.5 kg (14.3 lbs) with 2 batteries to 6.9 kg (15.3 lbs) |
Enclosure Material | 316 Stainless Steel |
Operating Temperature and Humidity | 0 to 40°C (32 to 104°F), 10 to 90% relative humidity, non-condensing |
Storage Temperature and Humidity | -20 to 50 degree C (-4 to 122 F), 0 to 98% relative humidity, non-condensing |
Screen | 10″ High Resolution LCD |
Interface | High sensitivity capacitive touch screen – works with dual gloves |
Alarms | Unlimited user defined alarms per channel or external environmental sensor |
Sampling Configuration Options | Sample by time or volume, up to 100 cycles, with user defined time intervals |
USB Host | 3 Type A USB 2.0 Host Ports |
USB Device | 1 Type B USB Device Port |
Ethernet | 1 802.3 Compliant 10/100 BASE-TX Auto negotiating with Auto MDI-X |
WiFi | 802.11 b/g 2.4 GHz WiFi Radio |
Environmental Probe | Proprietary DIN port for Relative Humidity and Temperature sensor probe PN 2088928 |
- Overview
-
MET ONE 3400+ particle counter
Automate environmental monitoring for GMP cleanroom compliance with ONE easy decision
The MET ONE 3400+ Series Portable Airborne Particle Counter features automated integrated electronic SOPs and sampling maps that reduce training requirements—and sampling errors. Using a web-browser interface, load your SOP map into the counter, mark sample locations, and define SOP requirements for each.
The MET ONE 3400+ helps you manage accurate cleanroom monitoring data via safe and secure internal software and web access—there’s no external software needed. All data is encrypted, and users are never permitted to delete records.
And because it uses Microsoft Active Directory for Username and Password Control for log-on and electronic signatures, it supports 21 CFR Part 11 compliance and ALCOA guidance.We live in an interconnected world, but for many GMP regulated devices to share data requires huge software integrations and validation. The MET ONE 3400+ has built-in, secure networking capabilities that are validated out of the box using our IQ / OQ protocols. A lightweight networking protocol securely protected via transport layer security (TLS) in the MET ONE 3400+ interconnects multiple devices and shares configuration and sample data in a secure and compliant manner. Ease the burden on your IT department with the new MET ONE 3400+ air particle counter.
- Customized Electronic SOP Maps
- Interactive Tracking
- Automated SOP Version Control
- Review and Approve
- Secure Electronic Records
- Barcode Function (optional)
- Plug-n-Play Networking
- Sampling Options
Applications
Cleanroom environmental monitoring – Aseptic pharmaceutical production – Continuous environmental monitoring – Process troubleshooting – HEPA filter leak detection – Hygiene Quality Control – Laboratory – Micro-electronic Industry
- Technical Specifications
-
models MET ONE 3413+ MET ONE 3415+ / MET ONE 3423+ METONE 3425+ MET ONE 3445+ Standard Sizes 0.3, 0.5, 1.0, 3.0, 5.0,
10.0 μm0.5, 1.0, 2.0, 3.0, 5.0,
10.0 μm0.5, 1.0, 2.0, 3.0, 5.0,
10.0 μm0.5, 1.0, 2.0, 3.0, 5.0,
10.0 μm0.5, 1.0, 2.0, 3.0, 5.0,
10.0 μmFlow Rate 28.3 LPM (1.0 CFM) 28.3 LPM (1.0 CFM) 50 LPM (1.77 CFM) 50 LPM (1.77 CFM) 100 LPM (3.53 CFM) Flow Rate Tolerance ±5% ±5% ±5% ±5% ±5% Time to sample 1 m³ 35.3 minutes 35.3 minutes 20 minutes 20 minutes 10 minutes Zero Count 1 count or less in 5 minutes,
95% confidence level1 count or less in 5 minutes,
95% confidence level1 count or less in 5 minutes,
95% confidence level1 count or less in 5 minutes,
95% confidence level1 count or less in 5 minutes,
95% confidence levelCoincidence Loss 10% at 36,000,000
particles per m³10% at 36,000,000
particles per m³10% at 20,000,000
particles per m³10% at 20,000,000
particles per m³10% at 10,000,000
particles per m³Counting Efficiency – 50% 50% ±20% for 0.3 μm 50% ±20% for 0.5 μm 50% ±20% for 0.3 μm 50% ±20% for 0.5 μm 50% ±20% for 0.5 μm Counting Efficiency – 100% 100% ±10% for
0.45 μm100% ±10% for
0.75 μm100% ±10% for
0.45 μm100% ±10% for
0.75 μm100% ±10% for
0.75 μmLight Source Long Life Laser™ diode with
10-year Mean Time To FailureLong Life Laser™ diode with
10-year Mean Time To FailureLong Life Laser™ diode with
10-year Mean Time To FailureLong Life Laser™ diode with
10-year Mean Time To FailureLong Life Laser™ diode with
10-year Mean Time To FailurePump Type Filtered to ISO 3 specifications, 3/8” NPT pipe fitting Filtered to ISO 3 specifications, 3/8” NPT pipe fitting Filtered to ISO 3 specifications, 3/8” NPT pipe fitting Filtered to ISO 3 specifications, 3/8” NPT pipe fitting Filtered to ISO 3 specifications, 3/8” NPT pipe fitting Exhaust 3/8″ NPT pipe fitting available 3/8″ NPT pipe fitting available 3/8″ NPT pipe fitting available 3/8″ NPT pipe fitting available 3/8″ NPT pipe fitting available AC Power Supply Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum Output: 24 VDC, 5.0 A Maximum; Input: 80-264 VAC, 47-63 Hz, 1.2 A Maximum Battery Type and Quantity 1, 2 or 3 Li Ion Rechargeable Smart Battery Packs 1, 2 or 3 Li Ion Rechargeable Smart Battery Packs 1, 2 or 3 Li Ion Rechargeable Smart Battery Packs 1, 2 or 3 Li Ion Rechargeable Smart Battery Packs 3 Li Ion Rechargeable
Smart Battery
PacksBattery Life (Continuous Sampling) w/ 1 Battery 3 hours 3 hours 3 hours 3 hours Pump will not
operateBattery Life (Continuous Sampling) w/ 2 Battery 6.25 hours 6.25 hours 6.5 hours 6.5 hours 4 hours Battery Life (Continuous Sampling) w/ 2 Battery 9.25 hours 9.25 hours 9.75 hours 9.75 hours 5.5 hours Maximum Battery Recharge Time 3.5 hours (with 2 batteries) 3.5 hours (with 2 batteries) 3.5 hours (with 2 batteries) 3.5 hours (with 2 batteries) 6.75 hours
(with 3 batteries)Dimensions (cm) 26.7 W x 26 H x 21 D Weight (without battery) 5.6 kg (12.4 lbs) Weight (with included batteries) 6.5 kg (14.3 lbs) with 2 batteries to 6.9 kg (15.3 lbs) Enclosure Material 316 Stainless Steel Operating Temperature and Humidity 0 to 40°C (32 to 104°F), 10 to 90% relative humidity, non-condensing Storage Temperature and Humidity -20 to 50 degree C (-4 to 122 F), 0 to 98% relative humidity, non-condensing Screen 10″ High Resolution LCD Interface High sensitivity capacitive touch screen – works with dual gloves Alarms Unlimited user defined alarms per channel or external environmental sensor Sampling Configuration Options Sample by time or volume, up to 100 cycles, with user defined time intervals USB Host 3 Type A USB 2.0 Host Ports USB Device 1 Type B USB Device Port Ethernet 1 802.3 Compliant 10/100 BASE-TX Auto negotiating with Auto MDI-X WiFi 802.11 b/g 2.4 GHz WiFi Radio Environmental Probe Proprietary DIN port for Relative Humidity and Temperature sensor probe PN 2088928 - Downloads