ATI TDA 100 Diluter : TDA-D SERIES AEROSOL DILUTERS

Designed for the specialized needs of the high efficiency particulate (HEPA) filter testing industry, the TDA-D Series aerosol diluters enhance the effectiveness of optical particle counters by diluting the upstream concentration of aerosol to measurable levels.

Placed between the aerosol source and a particle counter, these diluters minimize pressure drop and aerosol loss while preventing saturation of the particle counter.
Versatile technology The TDA-D series aerosol diluters are compatible with any 1cfm particle counter. They are available in 10:1 and 100:1 versions and work with any type of aerosol challenge, including PSL, PAO, DOP and NaCl. Each and every TDA-D Series Diluter is configured to customer specific requirements.
Product Configuration TDA-D Series Diluters are available in 10:1 and 100:1 dilution options and can be plumbed in series to achieve additional dilution configurations.

Emtek HPD2

HPD Material / Finish 316 Stainless Steel / Electro-polished
Equipment/Flow Compatibility V100/RCG (28.3, 50 & 100 LPM), P100 (28.3 & 100 LPM) 1
CFM, 28.3, 50, 75 and 100 LPM Laser Particle Counter (LPC)
HPD Pressure Ranges (Approx) V100/RCG, and LPC’s:
-1 CFM, 28.3, 50/15-18 to 125 PSI (1.3-8.6 bar)
-75 or 100 LPM/18-21 to 125 PSI (1.5-8.6 bar)
P100 (with Compressed Gas Kit)
-28.3 LPM / 6-80 PSI (0.5-6.5 bar)
-100 LPM / 26-110 PSI / 1.8 – 7.6 bar)
HPD Fittings/Adapters tubing to LPC & P100 or RCG/Outlet Side (Barb) 0.500”/0.375“/0.188“ OD (28.3/50 LPM for LPC’s) & 0.500“ OD (28.3/50 LPM for P100 or RCG), or 0.500“ OD (75/100 LPM)
Overview

ATI TDA 100 Diluter : TDA-D SERIES AEROSOL DILUTERS

Designed for the specialized needs of the high efficiency particulate (HEPA) filter testing industry, the TDA-D Series aerosol diluters enhance the effectiveness of optical particle counters by diluting the upstream concentration of aerosol to measurable levels.

Placed between the aerosol source and a particle counter, these diluters minimize pressure drop and aerosol loss while preventing saturation of the particle counter.
Versatile technology The TDA-D series aerosol diluters are compatible with any 1cfm particle counter. They are available in 10:1 and 100:1 versions and work with any type of aerosol challenge, including PSL, PAO, DOP and NaCl. Each and every TDA-D Series Diluter is configured to customer specific requirements.
Product Configuration TDA-D Series Diluters are available in 10:1 and 100:1 dilution options and can be plumbed in series to achieve additional dilution configurations.

Technical Specifications

Emtek HPD2

HPD Material / Finish 316 Stainless Steel / Electro-polished
Equipment/Flow Compatibility V100/RCG (28.3, 50 & 100 LPM), P100 (28.3 & 100 LPM) 1
CFM, 28.3, 50, 75 and 100 LPM Laser Particle Counter (LPC)
HPD Pressure Ranges (Approx) V100/RCG, and LPC’s:
-1 CFM, 28.3, 50/15-18 to 125 PSI (1.3-8.6 bar)
-75 or 100 LPM/18-21 to 125 PSI (1.5-8.6 bar)
P100 (with Compressed Gas Kit)
-28.3 LPM / 6-80 PSI (0.5-6.5 bar)
-100 LPM / 26-110 PSI / 1.8 – 7.6 bar)
HPD Fittings/Adapters tubing to LPC & P100 or RCG/Outlet Side (Barb) 0.500”/0.375“/0.188“ OD (28.3/50 LPM for LPC’s) & 0.500“ OD (28.3/50 LPM for P100 or RCG), or 0.500“ OD (75/100 LPM)
Download

Duke particles

Particulate matter for calibration of counting instruments or particle sizing instruments.

Quality control and calibration laboratories rely on DUKE particles as a reference for calibrating and verifying the performance of airborne and liquid particle counters.

  • High Precision
  • Superior uniformity
  • Excellent reproducibility
  • Long-term stability
  • NIST traceable (National Institute of Standard Technology, USA)
common features  Advantages
Certificate of Analysis and Traceability at National Institute of Standards and Technology (NIST) Permet aux laboratoires de démontrer la traçabilité de leurs méthodes analytiques conformément aux normes ISO, ANSI/NCSL Z540, BPF/BPL et autres normes et règlements
open platform Operates without bias or restriction for the most used brands or models of instruments
Superior uniformity of particle diameter Ensures a tight distribution of particle population size to provide more accurate calibration points when adjusting the calibration curve
Stability Reliable performance and results
Excellent batch to batch reproducibility
Packed in dropper bottles Easy to use; minimizes operator errors by providing accurate volume of balls in the instrument
Various polystyrene, silica and glass beads available in a wide range of sizes Meets a wide range of instrument needs and applications
Overview

Duke particles

Particulate matter for calibration of counting instruments or particle sizing instruments.

Quality control and calibration laboratories rely on DUKE particles as a reference for calibrating and verifying the performance of airborne and liquid particle counters.

  • High Precision
  • Superior uniformity
  • Excellent reproducibility
  • Long-term stability
  • NIST traceable (National Institute of Standard Technology, USA)
Technical Specifications
common features  Advantages
Certificate of Analysis and Traceability at National Institute of Standards and Technology (NIST) Permet aux laboratoires de démontrer la traçabilité de leurs méthodes analytiques conformément aux normes ISO, ANSI/NCSL Z540, BPF/BPL et autres normes et règlements
open platform Operates without bias or restriction for the most used brands or models of instruments
Superior uniformity of particle diameter Ensures a tight distribution of particle population size to provide more accurate calibration points when adjusting the calibration curve
Stability Reliable performance and results
Excellent batch to batch reproducibility
Packed in dropper bottles Easy to use; minimizes operator errors by providing accurate volume of balls in the instrument
Various polystyrene, silica and glass beads available in a wide range of sizes Meets a wide range of instrument needs and applications

Rechargeable lithium batteries for particle counters:

  • CLIMET CI-150 & CI-450
  • MET ONE 3400
  • MET ONE 3400+
  • LASAIR II (Reconditionned battery)
  • LASAIR III
Overview

Rechargeable lithium batteries for particle counters:

  • CLIMET CI-150 & CI-450
  • MET ONE 3400
  • MET ONE 3400+
  • LASAIR II (Reconditionned battery)
  • LASAIR III

External battery chargers for particle counters :

  • MET ONE 3400
  • LASAIR III
Overview

External battery chargers for particle counters :

  • MET ONE 3400
  • LASAIR III

230V power supply for Particle Counters :

  • MET ONE 3400
  • LASAIR III
Overview

230V power supply for Particle Counters :

  • MET ONE 3400
  • LASAIR III

Roll of special “clean room” paper for thermal printers of particle counters:

 

  • MET ONE 3400 serie
  • LASAIR II
  • LASAIR III
Overview

Roll of special “clean room” paper for thermal printers of particle counters:

 

  • MET ONE 3400 serie
  • LASAIR II
  • LASAIR III

Zero count filters for particle counters :

  • MET ONE 341x (28.3 LPM / 1 CFM), MET ONE 342x (50LPM)
  • MET ONE 3445 (100LPM)
  • MET ONE 6015, 6015P & 7015 (28.3 LPM / 1CFM)
  • MET ONE HHPC+ (2.8 LPM / 0.1CFM)
  • FLUKE 985 (2.8LPM / 0.1CFM)
  • LASAIR II 310A, 310B, 510A (28.3 LPM / 1CFM)
  • LASAIR II 350L & 550L (50LPM)
  • LASAIR III 310B & 310C (28.3 LPM / 1CFM)
  • LASAIR III 350L (50LPM)
  • LASAIR III 5100 (100LPM)
  • AIRNET 510 & AIRNET II 510 (28.3 LPM / 1CFM)
Overview

Zero count filters for particle counters :

  • MET ONE 341x (28.3 LPM / 1 CFM), MET ONE 342x (50LPM)
  • MET ONE 3445 (100LPM)
  • MET ONE 6015, 6015P & 7015 (28.3 LPM / 1CFM)
  • MET ONE HHPC+ (2.8 LPM / 0.1CFM)
  • FLUKE 985 (2.8LPM / 0.1CFM)
  • LASAIR II 310A, 310B, 510A (28.3 LPM / 1CFM)
  • LASAIR II 350L & 550L (50LPM)
  • LASAIR III 310B & 310C (28.3 LPM / 1CFM)
  • LASAIR III 350L (50LPM)
  • LASAIR III 5100 (100LPM)
  • AIRNET 510 & AIRNET II 510 (28.3 LPM / 1CFM)

Isokinetic probes

Stainless steel or Aluminium isokinetic probes with or without lid for particle counters :

  • MET ONE 341x (28.3 LPM / 1 CFM), MET ONE 342x (50LPM)
  • MET ONE 3445 (100LPM)
  • MET ONE 6015, 6015P & 7015 (28.3 LPM / 1CFM)
  • MET ONE HHPC+ (2.8 LPM / 0.1CFM)
  • FLUKE 985 (2.8 LPM / 0.1CFM)
  • LASAIR II 310A, 310B, 510A (28.3 LPM / 1CFM)
  • LASAIR II 350L & 550L (50LPM)
  • LASAIR III 310B & 310C (28.3 LPM / 1CFM)
  • LASAIR III 350L (50LPM)
  • LASAIR III 5100 (100LPM)
  • AIRNET 510 & AIRNET II 510 (28.3LPM /1CFM)
  • ISOAIR 510 PLUS & ISOAIR 310P (28.3 LPM /1CFM)
  • Other particle counters brands on request.
Overview

Isokinetic probes

Stainless steel or Aluminium isokinetic probes with or without lid for particle counters :

  • MET ONE 341x (28.3 LPM / 1 CFM), MET ONE 342x (50LPM)
  • MET ONE 3445 (100LPM)
  • MET ONE 6015, 6015P & 7015 (28.3 LPM / 1CFM)
  • MET ONE HHPC+ (2.8 LPM / 0.1CFM)
  • FLUKE 985 (2.8 LPM / 0.1CFM)
  • LASAIR II 310A, 310B, 510A (28.3 LPM / 1CFM)
  • LASAIR II 350L & 550L (50LPM)
  • LASAIR III 310B & 310C (28.3 LPM / 1CFM)
  • LASAIR III 350L (50LPM)
  • LASAIR III 5100 (100LPM)
  • AIRNET 510 & AIRNET II 510 (28.3LPM /1CFM)
  • ISOAIR 510 PLUS & ISOAIR 310P (28.3 LPM /1CFM)
  • Other particle counters brands on request.

Tubing

High conductivity antistatic tubing for EMTEK microbial air samplers and particle counters:

  • EMTEK P100, V100 & R100
  • MET ONE 341x (28.3 LPM /1 CFM), MET ONE 342x (50 LPM)
  • MET ONE 3445 (100 LPM)
  • MET ONE 6015, 6015P & 7015 (28.3 LPM /1CFM)
  • LASAIR II 310A, 310B, 510A (28.3 LPM /1CFM)
  • LASAIR II 350L & 550L (50 LPM)
  • LASAIR III 310B & 310C (28.3 LPM/1CFM)
  • LASAIR III 350L (50 LPM)
  • LASAIR III 5100 (100 LPM)
  • AIRNET 510 & AIRNET II 510 (28.3 LPM /1CFM)
  • ISOAIR 510 PLUS & ISOAIR 310P (28.3 LPM /1CFM)
Overview

Tubing

High conductivity antistatic tubing for EMTEK microbial air samplers and particle counters:

  • EMTEK P100, V100 & R100
  • MET ONE 341x (28.3 LPM /1 CFM), MET ONE 342x (50 LPM)
  • MET ONE 3445 (100 LPM)
  • MET ONE 6015, 6015P & 7015 (28.3 LPM /1CFM)
  • LASAIR II 310A, 310B, 510A (28.3 LPM /1CFM)
  • LASAIR II 350L & 550L (50 LPM)
  • LASAIR III 310B & 310C (28.3 LPM/1CFM)
  • LASAIR III 350L (50 LPM)
  • LASAIR III 5100 (100 LPM)
  • AIRNET 510 & AIRNET II 510 (28.3 LPM /1CFM)
  • ISOAIR 510 PLUS & ISOAIR 310P (28.3 LPM /1CFM)

Tripods:

  • Compact tripod for Isokinetic probe, handle particule counter, microbial air sampler and fog generator
  • Flexible tripod with suction cup for Isokinetic probe
Overview

Tripods:

  • Compact tripod for Isokinetic probe, handle particule counter, microbial air sampler and fog generator
  • Flexible tripod with suction cup for Isokinetic probe

Emtek HPD

“Hybrid” HPD for use with RCG and P100 for Microbial Testing,
and Laser Particle Counters for Total Particulate testing.

 

EMTEK Filtered Total Particulate/Microbial High Pressure Diffuser (HPD);

Emtek HPD2

HPD Material / Finish 316 Stainless Steel / Electro-polished
Equipment/Flow Compatibility V100/RCG (28.3, 50 & 100 LPM), P100 (28.3 & 100 LPM) 1
CFM, 28.3, 50, 75 and 100 LPM Laser Particle Counter (LPC)
HPD Pressure Ranges (Approx) V100/RCG, and LPC’s:
-1 CFM, 28.3, 50/15-18 to 125 PSI (1.3-8.6 bar)
-75 or 100 LPM/18-21 to 125 PSI (1.5-8.6 bar)
P100 (with Compressed Gas Kit)
-28.3 LPM / 6-80 PSI (0.5-6.5 bar)
-100 LPM / 26-110 PSI / 1.8 – 7.6 bar)
HPD Fittings/Adapters tubing to LPC & P100 or RCG/Outlet Side (Barb) 0.500”/0.375“/0.188“ OD (28.3/50 LPM for LPC’s) & 0.500“ OD (28.3/50 LPM for P100 or RCG), or 0.500“ OD (75/100 LPM)
Overview

Emtek HPD

“Hybrid” HPD for use with RCG and P100 for Microbial Testing,
and Laser Particle Counters for Total Particulate testing.

 

EMTEK Filtered Total Particulate/Microbial High Pressure Diffuser (HPD);

Technical Specifications

Emtek HPD2

HPD Material / Finish 316 Stainless Steel / Electro-polished
Equipment/Flow Compatibility V100/RCG (28.3, 50 & 100 LPM), P100 (28.3 & 100 LPM) 1
CFM, 28.3, 50, 75 and 100 LPM Laser Particle Counter (LPC)
HPD Pressure Ranges (Approx) V100/RCG, and LPC’s:
-1 CFM, 28.3, 50/15-18 to 125 PSI (1.3-8.6 bar)
-75 or 100 LPM/18-21 to 125 PSI (1.5-8.6 bar)
P100 (with Compressed Gas Kit)
-28.3 LPM / 6-80 PSI (0.5-6.5 bar)
-100 LPM / 26-110 PSI / 1.8 – 7.6 bar)
HPD Fittings/Adapters tubing to LPC & P100 or RCG/Outlet Side (Barb) 0.500”/0.375“/0.188“ OD (28.3/50 LPM for LPC’s) & 0.500“ OD (28.3/50 LPM for P100 or RCG), or 0.500“ OD (75/100 LPM)