MPRF Temperature

Adaptable to almost any situation, the DataTrace MPRF Temperature data logger’s small size increases versatility and precision by allowing you to position the data logger very near or inside your target products.

MPRF Temperature strong points:

  • Wireless Temperature Data Loggers
  • 10 Point Temp NIST Traceable Calibration
  • Real-Time Data
  • FDA 21 CFR Part 11 compliant software

 

Applications

Smokehouses – Pasteurizers – Lyophilizers – Sterilizers – Freezers – Incubators – Autoclaves – Cooking and drying tunnels –

MPRF Temperature

 

Operating Temperature:
-80°C to +140°C (-112°F to +284°F)*
Temperature Accuracy:
-80°C to -40°C (-112°F to -40°F):±0.3°C (±0.5°F)
-40°C to +140°C (-40°F to +284°F):±0.1°C (±0.2°F)
Resolution:
 0.001°C
Operating Pressure:
Up to 10 BAR
Wireless Range:
 100 feet (30 meters) Line of Sight
Radio Frequency: 2.4 GHz ISM Band
Size:
Width: 0.91 in (23.2mm)
Length: 3.7 in (94mm)**
Weight: 2.3 oz (66 grams)**
Material: stainless steel and ULTEM
Probe Diameter:
Rigid probe diameter: 0.125”/3.2mm or .188” (4.76mm) available
Bendable probe diameter: 0.079”/2mm
Temperature: PT1000 Class A RTD
Calibration: Factory calibrated (NIST traceable) or Field Calibration
Battery Type: AA Lithium (field-replaceable)
Battery Life: 6 months to 1 year (depending on usage)
Battery Weight:

 

Standard Temperature Battery: 0.6 oz (17 grams)
Low Temperature Battery: 0.67 oz (19 grams)
Clock accuracy: 10 seconds per 24 hours (25°C)
Certifications:
ATEX (for intrinsic safety)
FCC Class B digital device (part 15 compliance)
Memory
8,192 time/temperature observations or 16,384 observations in compressed data mode
Sample rate
Operator programmable
• 5 sec. to 1 hr interval with radio
• 1 sec. to 1 hr interval without radio
*Operation below -40°C requires a special calibration and battery.
**Body only.
***Thermal Packs required above +140°C
Overview

MPRF Temperature

Adaptable to almost any situation, the DataTrace MPRF Temperature data logger’s small size increases versatility and precision by allowing you to position the data logger very near or inside your target products.

MPRF Temperature strong points:

  • Wireless Temperature Data Loggers
  • 10 Point Temp NIST Traceable Calibration
  • Real-Time Data
  • FDA 21 CFR Part 11 compliant software

 

Applications

Smokehouses – Pasteurizers – Lyophilizers – Sterilizers – Freezers – Incubators – Autoclaves – Cooking and drying tunnels –

Technical Specifications

MPRF Temperature

 

Operating Temperature:
-80°C to +140°C (-112°F to +284°F)*
Temperature Accuracy:
-80°C to -40°C (-112°F to -40°F):±0.3°C (±0.5°F)
-40°C to +140°C (-40°F to +284°F):±0.1°C (±0.2°F)
Resolution:
 0.001°C
Operating Pressure:
Up to 10 BAR
Wireless Range:
 100 feet (30 meters) Line of Sight
Radio Frequency: 2.4 GHz ISM Band
Size:
Width: 0.91 in (23.2mm)
Length: 3.7 in (94mm)**
Weight: 2.3 oz (66 grams)**
Material: stainless steel and ULTEM
Probe Diameter:
Rigid probe diameter: 0.125”/3.2mm or .188” (4.76mm) available
Bendable probe diameter: 0.079”/2mm
Temperature: PT1000 Class A RTD
Calibration: Factory calibrated (NIST traceable) or Field Calibration
Battery Type: AA Lithium (field-replaceable)
Battery Life: 6 months to 1 year (depending on usage)
Battery Weight:

 

Standard Temperature Battery: 0.6 oz (17 grams)
Low Temperature Battery: 0.67 oz (19 grams)
Clock accuracy: 10 seconds per 24 hours (25°C)
Certifications:
ATEX (for intrinsic safety)
FCC Class B digital device (part 15 compliance)
Memory
8,192 time/temperature observations or 16,384 observations in compressed data mode
Sample rate
Operator programmable
• 5 sec. to 1 hr interval with radio
• 1 sec. to 1 hr interval without radio
*Operation below -40°C requires a special calibration and battery.
**Body only.
***Thermal Packs required above +140°C
Downloads
Contact Quote request