MPIII Temperature
Miniaturized Data logger
MPIII Temperature DataTrace provide accurate data over a wide range with remarkable ease.
Their small size increases versatility and precision by allowing you to position Loggers very near or inside monitored items.
- 16,000 NIST-traceable Data Points
- FDA 21 CFR Part 11 Compliant Software
- Intrinsically Safe
Applications
Process equipment and sterilization – Foods – Canning – Beverages – Pharmaceuticals – Monitoring & testing compressed gas systems – Pressurized process reactor and streams – Medical – Sterilizer validation – Textile manufacturing – Thermal processing for electronic, chemical, aerospace and other industries – Product handling and storage
MPIII Temperature |
|
Size: |
Width: 0.7 in. (18mm) Length: 0.9 in. (23mm)**
|
Weight:
|
0.5 oz. (15 grams)**
|
Material: |
316 stainless steel; Sapphire IR windows
|
Memory: |
16,000 time/temperature observations
|
Sample rates |
Operator programmable 1 sec. to 1 hr. intervals
|
Temperature Accuracy:
|
MPIII Temp/Dual: ±0.1°C (±.2°F)
|
Operating Temperatures:
|
MPIII Temp and MPIII Dual Temp: -20°C (-4°F) to +140°C (+284°F)
|
Operating Pressure:
|
For all 3 models: Up to 10 Bar
|
Calibration:
|
Factory calibrated (NIST traceable) Field calibration (MPIII Temp/Dual only)
|
Battery Type:
|
Lithium (field-replaceable)
|
Clock accuracy:
|
26 seconds per 24 hours
|
Certifications:
|
ATEX (for intrinsic safety)
|
**Size and weight are shown for Logger body only.
- Overview
-
MPIII Temperature
Miniaturized Data logger
MPIII Temperature DataTrace provide accurate data over a wide range with remarkable ease.Their small size increases versatility and precision by allowing you to position Loggers very near or inside monitored items.- 16,000 NIST-traceable Data Points
- FDA 21 CFR Part 11 Compliant Software
- Intrinsically Safe
Applications
Process equipment and sterilization – Foods – Canning – Beverages – Pharmaceuticals – Monitoring & testing compressed gas systems – Pressurized process reactor and streams – Medical – Sterilizer validation – Textile manufacturing – Thermal processing for electronic, chemical, aerospace and other industries – Product handling and storage
- Technical Specifications
-
MPIII Temperature
Size: Width: 0.7 in. (18mm) Length: 0.9 in. (23mm)**Weight:0.5 oz. (15 grams)**Material: 316 stainless steel; Sapphire IR windowsMemory: 16,000 time/temperature observationsSample rates Operator programmable 1 sec. to 1 hr. intervalsTemperature Accuracy:MPIII Temp/Dual: ±0.1°C (±.2°F)Operating Temperatures:MPIII Temp and MPIII Dual Temp: -20°C (-4°F) to +140°C (+284°F)Operating Pressure:For all 3 models: Up to 10 BarCalibration:Factory calibrated (NIST traceable)
Field calibration (MPIII Temp/Dual only)Battery Type:Lithium (field-replaceable)Clock accuracy:26 seconds per 24 hoursCertifications:ATEX (for intrinsic safety)**Size and weight are shown for Logger body only. - Downloads