MPIII HiTemp Logger
Adaptable to almost any situation, MPIII High Temperature DataTrace logger measure less than an inch (without probe or Thermal Pack). Their small size increases versatility and precision by allowing you to position loggers very near or inside monitored items. From chilling, freezing and room temperature to pasteurization, EtO sterilization and depyrogenation, MPIII Temp, HiTemp and HiTemp EXT loggers provide accurate data over a wide range with remarkable ease.
Applications
Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room
MPIII HiTemp Logger |
|
Size: |
Width: 0.7 in. (18mm) Length: 0.9 in. (23mm)**
|
Weight:
|
0.5 oz. (15 grams)**
|
Material: |
316 stainless steel; Sapphire IR windows
|
Memory: |
16,000 time/temperature observations
|
Sample rates |
Operator programmable 1 sec. to 1 hr. intervals
|
Temperature Accuracy:
|
MPIII HiTemp*: ± 0.5°C (±0.9°F)
MPIII HiTemp EXT*: ± 0.25°C (±0.45°F); <200°C (392°F) ± 0.5°C (±0.9°F); ≥200°C (392°F)
|
Operating Temperatures:
|
MPIII HiTemp*: +100°C (+212°F) to +360°C (+680°F) w/Thermal Pack
MPIII HiTemp EXT*: -20°C (-4°F) to +400°C (+752°F) w/Thermal Pack
|
Operating Pressure:
|
For all 3 models: Up to 10 Bar
|
Calibration:
|
Factory calibrated (NIST traceable) Field calibration (MPIII Temp/Dual only)
|
Battery Type:
|
Lithium (field-replaceable)
|
Clock accuracy:
|
26 seconds per 24 hours
|
Certifications:
|
ATEX (for intrinsic safety)
|
**Size and weight are shown for Logger body only.
- Overview
-
MPIII HiTemp Logger
Adaptable to almost any situation, MPIII High Temperature DataTrace logger measure less than an inch (without probe or Thermal Pack). Their small size increases versatility and precision by allowing you to position loggers very near or inside monitored items. From chilling, freezing and room temperature to pasteurization, EtO sterilization and depyrogenation, MPIII Temp, HiTemp and HiTemp EXT loggers provide accurate data over a wide range with remarkable ease.
Applications
Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room
- Technical Specifications
-
MPIII HiTemp Logger
Size: Width: 0.7 in. (18mm) Length: 0.9 in. (23mm)**Weight:0.5 oz. (15 grams)**Material: 316 stainless steel; Sapphire IR windowsMemory: 16,000 time/temperature observationsSample rates Operator programmable 1 sec. to 1 hr. intervalsTemperature Accuracy:MPIII HiTemp*: ± 0.5°C (±0.9°F)MPIII HiTemp EXT*: ± 0.25°C (±0.45°F); <200°C (392°F) ± 0.5°C (±0.9°F); ≥200°C (392°F)Operating Temperatures:MPIII HiTemp*: +100°C (+212°F) to +360°C (+680°F) w/Thermal PackMPIII HiTemp EXT*: -20°C (-4°F) to +400°C (+752°F) w/Thermal PackOperating Pressure:For all 3 models: Up to 10 BarCalibration:Factory calibrated (NIST traceable)
Field calibration (MPIII Temp/Dual only)Battery Type:Lithium (field-replaceable)Clock accuracy:26 seconds per 24 hoursCertifications:ATEX (for intrinsic safety)*Hi Temp & Hi Temp EXT Loggers require a Thermal Pack for use above +140°C**Size and weight are shown for Logger body only.