UTRIX-16

Multi-Use USB PDF Temperature recorder -30°C to +70°C

Data Logger with integral USB connector. The LogTag UTRIX-16 requires no special hardware or proprietary software to access the recorded data and can generate a fully detailed PDF report.

It sotores real-timz temperature readings over a measurement range of -30°C to +70°C, displays user-configurable alerts, and comes with an integrated, long-life USB connector. The UTRIX-16 is enclosed in the same robust and durable polycarbonate case common to other LogTag products.

Products Highlights

  • Automatically generates a PDF report and an Excel data file – no special download software required.
  • Automatically generates an encrypted LogTag data file – for a more detailed analysis and to comply with FDA CFR21 Part 11.
  • Fully user configurable via LogTag Analyzer for individual alarm settings, start options, trip length and log interval.
  • Durable, reliable USB connector with gold plated contacts, designed for multiple insertions.
  • Up to 16,129 recordings – provides over 3 months logging at 10 minute sample intervals.
  • Suitable for any multi-use application where the recorder can be recovered and reused.

Applications

Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room

UTRIX-16

Sensor Measurement Range -30°C to +70°C (-13°F to +158°F)
Operating Temperature Range -30°C to +70°C (-13°F to +158°F).
Storage Temperature Range 0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F).
Better than ±0.7°C (±1.3°F) for -30°C to -20°C (-13°F to -4°F) & +40°C to +60°C (+104°F to +140°F).
Better than ±0.8°C (±1.5°F) for +60°C to +70°C (+140°F to +158°F).
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution Less than 0.1°C/F.
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 7 minutes (T90) in moving air (1m/s) in EN12830:1999.
Recording Capacity 16,129 temperature readings. 56 days @ 5min logging, 168 days @ 15min logging.
Sampling Interval Configurable from 30 seconds to 18 hours.
Logging Start Options Push button start (with configurable start delay from 1 minute to 72 hours) or specific date & time.
Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
Download Time Typically with full memory (16,129 readings) in less than 30 seconds from time of insertion to availability of PDF report.
Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured).
Environmental IEC 60529: IP64 with USB cap fitted.
Power Source 3V Li-Mg Battery.
Battery Life Typically 2 – 3 years with normal use (15 minute sampling interval, download data monthly), provided Logger is kept within the Storage Temperature Range when not in use.
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Connection Interface USB 2.0, A-type plug
Software PDF Reader, LogTag® Analyzer 2.5 or higher
Size 93mm(H) x 54.5mm(W) x 8.6mm(T) including protective USB cap.
Weight 36g.
Case Material Polycarbonate.
Compliance and Certifications CFRPart11  FCCCE   RoHS

Overview

UTRIX-16

Multi-Use USB PDF Temperature recorder -30°C to +70°C

Data Logger with integral USB connector. The LogTag UTRIX-16 requires no special hardware or proprietary software to access the recorded data and can generate a fully detailed PDF report.

It sotores real-timz temperature readings over a measurement range of -30°C to +70°C, displays user-configurable alerts, and comes with an integrated, long-life USB connector. The UTRIX-16 is enclosed in the same robust and durable polycarbonate case common to other LogTag products.

Products Highlights

  • Automatically generates a PDF report and an Excel data file – no special download software required.
  • Automatically generates an encrypted LogTag data file – for a more detailed analysis and to comply with FDA CFR21 Part 11.
  • Fully user configurable via LogTag Analyzer for individual alarm settings, start options, trip length and log interval.
  • Durable, reliable USB connector with gold plated contacts, designed for multiple insertions.
  • Up to 16,129 recordings – provides over 3 months logging at 10 minute sample intervals.
  • Suitable for any multi-use application where the recorder can be recovered and reused.

Applications

Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room

Technical Specifications

UTRIX-16

Sensor Measurement Range -30°C to +70°C (-13°F to +158°F)
Operating Temperature Range -30°C to +70°C (-13°F to +158°F).
Storage Temperature Range 0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F).
Better than ±0.7°C (±1.3°F) for -30°C to -20°C (-13°F to -4°F) & +40°C to +60°C (+104°F to +140°F).
Better than ±0.8°C (±1.5°F) for +60°C to +70°C (+140°F to +158°F).
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution Less than 0.1°C/F.
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 7 minutes (T90) in moving air (1m/s) in EN12830:1999.
Recording Capacity 16,129 temperature readings. 56 days @ 5min logging, 168 days @ 15min logging.
Sampling Interval Configurable from 30 seconds to 18 hours.
Logging Start Options Push button start (with configurable start delay from 1 minute to 72 hours) or specific date & time.
Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
Download Time Typically with full memory (16,129 readings) in less than 30 seconds from time of insertion to availability of PDF report.
Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured).
Environmental IEC 60529: IP64 with USB cap fitted.
Power Source 3V Li-Mg Battery.
Battery Life Typically 2 – 3 years with normal use (15 minute sampling interval, download data monthly), provided Logger is kept within the Storage Temperature Range when not in use.
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Connection Interface USB 2.0, A-type plug
Software PDF Reader, LogTag® Analyzer 2.5 or higher
Size 93mm(H) x 54.5mm(W) x 8.6mm(T) including protective USB cap.
Weight 36g.
Case Material Polycarbonate.
Compliance and Certifications CFRPart11  FCCCE   RoHS

Downloads
Contact Quote request