LogTag UTREL 30-16

The LogTag® UTREL30-16 Temperature Recorder measures and stores up to 16,000 temperature readings.
It features a large easy-to-read display and is designed to show ‘at a glance’ if temperature excursions have occurred during the current day and up to the previous 29 days.
The alarm is triggered if temperature readings are outside pre-set alarm limits which is indicated by a large X on the display and, if configured, the audible alarm will sound.

 

  • Read current temperature and latest Min-Max temperature at a glance
  • Audible alarm and flashing red LED signals a temperature alarm
  • Can be powered by 2x AAA batteries (user replaceable) if not external powered
  • Auto-pause function suspends alarm & statistic processing when the external sensor is unplugged
  • Download data via LogTag Analyzer or as a PDF (no software required).
  • Check and reset Min-Max temperature reading at any time
  • View alarm status for up to 30 days at a glance
  • Second battery backup via a coin cell to ensure no data is lost

 

Applications

Vaccine & Pharmaceuticals – Industrial – Cold Room – Clinic – Transportation – Refrigerated Containers

UTREL30-16

Sensor Measurement Range -90°C to +40°C (-130°F to +104°F).
Operating Temperature Range -30°C to +60°C (-22°F to +140°F).
Storage Temperature Range 0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Resolution 0.1°C (0.2°F) for measurements -80°C to 10°C (-112°F to 50°F).
0.2°C (0.4°F) for measurements 10°C to 20°C (50°F to 68°F) and -90°C to -80°C (-130°F to -112°F).
0.3°C (0.5°F) for measurements 20°C to 30°C (68°F to 86°F).
0.5°C (0.9°F) for measurements 30°C to 40°C (86°F to 104°F).
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Rated Temperature Reading Accuracy Better than ±0.5°C for -20°C to +10°C (-4°F to 50°F)
Better than ±0.7°C for -50°C to -20°C (-58°F to -4°F) and +10°C to +30°C (50°F to 86°F)
Better than ±1°C for -80°C to -50°C (-112°F to -58°F ) and +30°C to +40°C (86°F to 104°F)
Better than ±1.8°C for -90°C to -80°C (-130°F to -112°F)
Sampling Interval Configurable from 30 seconds to 18 hours.
Logging Start Options Push button start (with configurable start delay from 1 minute to 72 hours) or specific date & time.
Recording Capacity 16,129 temperature readings. 67 days at 6 minute logging.
Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics.
Download Time Typically with full memory (16,129 readings) in less than 10 seconds.
Environmental IP51 (when vertically mounted or hung with USB dust-cap in place).
Power Source 5V via micro USB socket or 2 x 1.5V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only).
Battery Life AAA battery up to 12 months – if unit is operated without power supply.
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Standard Remote Probe Cable Lengths Standard: 1.5m (4’11”). Extended: 3m (9’10”) (recommended maximum).
Remote Sensor Cable Type PTFE (FDA food contact rated) coaxial.
Connection Interface USB 2.0 / Micro USB Socket.
Software PDF Reader, LogTag® Analyzer 3.1.9 or higher.
PDF Report One page report with trip and alarm summary. Multi-page report with list of readings, including date and time.
Size 123mm(H) x 63mm(W) x 12.5mm(T).
Weight 250g with AAA batteries, (80g – excluding probe and AAA batteries).
Case Material Polycarbonate.
Compliance and Certifications FDA CFR21 Part 11 FCC EMC Directive CE EMC Directives Conforms to RoHS
Overview

LogTag UTREL 30-16

The LogTag® UTREL30-16 Temperature Recorder measures and stores up to 16,000 temperature readings.
It features a large easy-to-read display and is designed to show ‘at a glance’ if temperature excursions have occurred during the current day and up to the previous 29 days.
The alarm is triggered if temperature readings are outside pre-set alarm limits which is indicated by a large X on the display and, if configured, the audible alarm will sound.

 

  • Read current temperature and latest Min-Max temperature at a glance
  • Audible alarm and flashing red LED signals a temperature alarm
  • Can be powered by 2x AAA batteries (user replaceable) if not external powered
  • Auto-pause function suspends alarm & statistic processing when the external sensor is unplugged
  • Download data via LogTag Analyzer or as a PDF (no software required).
  • Check and reset Min-Max temperature reading at any time
  • View alarm status for up to 30 days at a glance
  • Second battery backup via a coin cell to ensure no data is lost

 

Applications

Vaccine & Pharmaceuticals – Industrial – Cold Room – Clinic – Transportation – Refrigerated Containers

Technical Specifications

UTREL30-16

Sensor Measurement Range -90°C to +40°C (-130°F to +104°F).
Operating Temperature Range -30°C to +60°C (-22°F to +140°F).
Storage Temperature Range 0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Resolution 0.1°C (0.2°F) for measurements -80°C to 10°C (-112°F to 50°F).
0.2°C (0.4°F) for measurements 10°C to 20°C (50°F to 68°F) and -90°C to -80°C (-130°F to -112°F).
0.3°C (0.5°F) for measurements 20°C to 30°C (68°F to 86°F).
0.5°C (0.9°F) for measurements 30°C to 40°C (86°F to 104°F).
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Rated Temperature Reading Accuracy Better than ±0.5°C for -20°C to +10°C (-4°F to 50°F)
Better than ±0.7°C for -50°C to -20°C (-58°F to -4°F) and +10°C to +30°C (50°F to 86°F)
Better than ±1°C for -80°C to -50°C (-112°F to -58°F ) and +30°C to +40°C (86°F to 104°F)
Better than ±1.8°C for -90°C to -80°C (-130°F to -112°F)
Sampling Interval Configurable from 30 seconds to 18 hours.
Logging Start Options Push button start (with configurable start delay from 1 minute to 72 hours) or specific date & time.
Recording Capacity 16,129 temperature readings. 67 days at 6 minute logging.
Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics.
Download Time Typically with full memory (16,129 readings) in less than 10 seconds.
Environmental IP51 (when vertically mounted or hung with USB dust-cap in place).
Power Source 5V via micro USB socket or 2 x 1.5V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only).
Battery Life AAA battery up to 12 months – if unit is operated without power supply.
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Standard Remote Probe Cable Lengths Standard: 1.5m (4’11”). Extended: 3m (9’10”) (recommended maximum).
Remote Sensor Cable Type PTFE (FDA food contact rated) coaxial.
Connection Interface USB 2.0 / Micro USB Socket.
Software PDF Reader, LogTag® Analyzer 3.1.9 or higher.
PDF Report One page report with trip and alarm summary. Multi-page report with list of readings, including date and time.
Size 123mm(H) x 63mm(W) x 12.5mm(T).
Weight 250g with AAA batteries, (80g – excluding probe and AAA batteries).
Case Material Polycarbonate.
Compliance and Certifications FDA CFR21 Part 11 FCC EMC Directive CE EMC Directives Conforms to RoHS