demande de devis

Logtag® USRIC-16

Single-Use PDF USB Temperature Logger

The LogTag USRIC-16 is a single use, cost effective & reliable temperature recorder. It measure and stores real time temperature readings over a measurement range of 30°C to 60°C.

The LogTag® USRIC-16 combines all the features of an advanced temperature recorder with a 16,000 log memory with a shelf life of up to two years before configuration (in standard hibernation mode) and a 6-month fixed battery operating life.

A red ALERT indicator provides an immediate indication – without access to a PC – if any readings are outside the limits specified at the time the unit was configured. A green OK indicator provides immediate visual confirmation that the unit is operating.

  • Up to 16,000 recordings – enough for the longest trip.
  • Integral USB connector – no separate Interface Cradle required.
  • Suitable for multiple independent receivers, clinical trials and last-mile distribution.
  • Automatically generates a PDF report – no special software required.

 

Product Model USRIC-16.
Sensor Measurement Range -30°C to +60°C (-22°F to +140°F).
Operating Temperature Range -30°C to +60°C (-22°F to +140°F).*
Storage Temperature Range 0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -5°C to +30°C (23°F to +86°F).
Better than ±0.8°C or better for measurements in other areas of rated range.
Actual performance is typically much better than the rated values.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution < 0.1°C/F.
LogTag® Analyzer currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 7 minutes (T90) in moving air (1m/s) EN12830:1999.
Recording Capacity 16,129 temperature readings. 56 days @ 5min logging, 168 days @ 15min logging.
Sampling Interval Logging interval is configurable from 1 minute to 18 hours. (Typically 5 minute logging).
Logging Start Options Push button start or specific date & time.
Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
Download Time Typically in less than 20 seconds from time of insertion to availability of PDF report.
Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured).
Environmental IEC 60529: IP64 with USB cap fitted.
Power Source CR2032 3V LiMnO2 Battery (Fixed).
Battery Life 2 years storage, followed by 6 months normal use.
Real Time Clock Built-in real time clock.
Typical accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Connection Interface USB 2.0, A-type plug.
Software PDF Reader, LogTag® Analyzer 2.5 or higher.
Size 93mm(H) x 54.5mm(W) x 8.6mm(T) including protective USB cap.
Weight 31g.
Case Material Polycarbonate.
Overview

Logtag® USRIC-16

Single-Use PDF USB Temperature Logger

The LogTag USRIC-16 is a single use, cost effective & reliable temperature recorder. It measure and stores real time temperature readings over a measurement range of 30°C to 60°C.

The LogTag® USRIC-16 combines all the features of an advanced temperature recorder with a 16,000 log memory with a shelf life of up to two years before configuration (in standard hibernation mode) and a 6-month fixed battery operating life.

A red ALERT indicator provides an immediate indication – without access to a PC – if any readings are outside the limits specified at the time the unit was configured. A green OK indicator provides immediate visual confirmation that the unit is operating.

  • Up to 16,000 recordings – enough for the longest trip.
  • Integral USB connector – no separate Interface Cradle required.
  • Suitable for multiple independent receivers, clinical trials and last-mile distribution.
  • Automatically generates a PDF report – no special software required.

 

Technical specification
Product Model USRIC-16.
Sensor Measurement Range -30°C to +60°C (-22°F to +140°F).
Operating Temperature Range -30°C to +60°C (-22°F to +140°F).*
Storage Temperature Range 0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -5°C to +30°C (23°F to +86°F).
Better than ±0.8°C or better for measurements in other areas of rated range.
Actual performance is typically much better than the rated values.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution < 0.1°C/F.
LogTag® Analyzer currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 7 minutes (T90) in moving air (1m/s) EN12830:1999.
Recording Capacity 16,129 temperature readings. 56 days @ 5min logging, 168 days @ 15min logging.
Sampling Interval Logging interval is configurable from 1 minute to 18 hours. (Typically 5 minute logging).
Logging Start Options Push button start or specific date & time.
Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
Download Time Typically in less than 20 seconds from time of insertion to availability of PDF report.
Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured).
Environmental IEC 60529: IP64 with USB cap fitted.
Power Source CR2032 3V LiMnO2 Battery (Fixed).
Battery Life 2 years storage, followed by 6 months normal use.
Real Time Clock Built-in real time clock.
Typical accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Connection Interface USB 2.0, A-type plug.
Software PDF Reader, LogTag® Analyzer 2.5 or higher.
Size 93mm(H) x 54.5mm(W) x 8.6mm(T) including protective USB cap.
Weight 31g.
Case Material Polycarbonate.
Download
Contact Quote request