LIBERO CE

Multi-Level and Multi-Use PDF Logger with USB interface for external Pt100 Probe

 

LIBERO CE is the ideal PDF Logger to simplify storage and shipment process for products with known stability data. It coversa wide measurement range from -200 °C to +400 °C and monitors temperature of cell and drug deliveries with cryogenic containers, dry ice or other applications using an external Pt100 probe. Supporting up to eight temperature alarm zones, MKT and duration as alarm criteria – LIBERO CE allows you to create temperature profiles for individual products. In addition, you have the option to switch the alarming function off and on again if alarming criteria is required. This can be useful in cases where a transportation box has been cleaned, or liquid nitrogen has been refilled in a cryogenic container.

LIBERO CE is reconfigurable and reusable for up to 3 years. The external Pt100 probe and M8 connector enables reliable, superior temperature data transfer to the data logger. Up to 75’500 temperature values can be stored on the data logger. LIBERO CE can be ordered with an optional stainless steel bracket. Release products with confidence based on the OK or ALARM status on the display and download the PDF report via the convenient USB interface without any additional software being required.

LIBERO CE

 

Type PDF Logger with USB interface for external Pt100 temperature probe (probe not included)
Application area Site Monitoring, Container Monitoring, Cryo Container Monitoring, Dry-ice Container Monitoring
Recording options and mode Multiple use: start/stop or loop mode
Type of probe Pt100 probe (4-wire measuring technique), max. cable length 3 m (118.1 inch), requires M8 connector
Measurement range Measurement range (depending on probe): -200°C..+400°C
Operating range of data logger: -30 °C..+70 °C
Measurement accuracy System accuracy*:

± 1.4 °C in the range of -200°C..-100.1°C (Class B)          ±0.5°C in the range of +25.1°C..+100°C (Class A)
± 1°C in the range of -100°C..-50.1°C (Class B)                ± 0.7°C in the range of +100.1°C..+200°C (Class A)
± 0.4°C in the range of -50°C..-10.1°C (Class A)               ± 1.1°C in the range of +200.1°C..+400°C (Class A)
± 0.3°C in the range of -10.0 °C..+25.0 °C (Class A)
*Includes data logger and external Pt100 probe of stated class

Measurement interval 1 to 60 minutes, user configurable
Memory capacity 75’500 measurement values (equals logging duration of 17 months at 10
Battery life 3 years
Battery type Button cell contained in equipment UN3091, exempt from DGR declaration Non-replaceable battery
Configurable alarms 8 temperature alarm zones with single or cumulative delays, Alarm on MKT, Alarm on duration/run time
Start-up delay User configurable based on time or temperature
Display Multifunction LCD, size: 22 × 22 mm, with OK and Alarm indicator
Certificate Certificate available on demand
Optional: Additional customer-specific calibration points according to ISO 17025 standard
Traceability Unique ID number (traceable to component level)
Report Built-in PDF file generator automatically establishes an evaluation report with embedded data upon connection to a USB port.
Complies with the ISO standard 19005-1 Document Management for the long-term preservation of electronic documents (PDF/A) and FDA 21 CFR Part 11.
– Customizable report title and filename
– Text area for additional information (e.g. shipment information, instructions for recipient, etc.)
– Statistics (min/max, average, alarm, alarming on/off) and detailed logger information (ID, configuration, etc.)
– Chart visualizing the temperature curve and alarm limits
Case
Dimension
Weight
BS plastic material
95 × 41 × 11 mm (241.3 x 104.1 x 27.9 inch), cable tail 85 mm (3.35 inch) including M8 connector
44 g (0.1 lb)
Accessories LIBERO CE stainless steel bracket, variety of Pt100 probes, extension cable with M8 connector
Conformity
Standards
E | FCC | RoHS | Safe Transport of Chemical Goods | WEEE

RTCA DO-160 | GAMP5

Overview

LIBERO CE

Multi-Level and Multi-Use PDF Logger with USB interface for external Pt100 Probe

 

LIBERO CE is the ideal PDF Logger to simplify storage and shipment process for products with known stability data. It coversa wide measurement range from -200 °C to +400 °C and monitors temperature of cell and drug deliveries with cryogenic containers, dry ice or other applications using an external Pt100 probe. Supporting up to eight temperature alarm zones, MKT and duration as alarm criteria – LIBERO CE allows you to create temperature profiles for individual products. In addition, you have the option to switch the alarming function off and on again if alarming criteria is required. This can be useful in cases where a transportation box has been cleaned, or liquid nitrogen has been refilled in a cryogenic container.

LIBERO CE is reconfigurable and reusable for up to 3 years. The external Pt100 probe and M8 connector enables reliable, superior temperature data transfer to the data logger. Up to 75’500 temperature values can be stored on the data logger. LIBERO CE can be ordered with an optional stainless steel bracket. Release products with confidence based on the OK or ALARM status on the display and download the PDF report via the convenient USB interface without any additional software being required.

Technical Specifications

LIBERO CE

 

Type PDF Logger with USB interface for external Pt100 temperature probe (probe not included)
Application area Site Monitoring, Container Monitoring, Cryo Container Monitoring, Dry-ice Container Monitoring
Recording options and mode Multiple use: start/stop or loop mode
Type of probe Pt100 probe (4-wire measuring technique), max. cable length 3 m (118.1 inch), requires M8 connector
Measurement range Measurement range (depending on probe): -200°C..+400°C
Operating range of data logger: -30 °C..+70 °C
Measurement accuracy System accuracy*:

± 1.4 °C in the range of -200°C..-100.1°C (Class B)          ±0.5°C in the range of +25.1°C..+100°C (Class A)
± 1°C in the range of -100°C..-50.1°C (Class B)                ± 0.7°C in the range of +100.1°C..+200°C (Class A)
± 0.4°C in the range of -50°C..-10.1°C (Class A)               ± 1.1°C in the range of +200.1°C..+400°C (Class A)
± 0.3°C in the range of -10.0 °C..+25.0 °C (Class A)
*Includes data logger and external Pt100 probe of stated class

Measurement interval 1 to 60 minutes, user configurable
Memory capacity 75’500 measurement values (equals logging duration of 17 months at 10
Battery life 3 years
Battery type Button cell contained in equipment UN3091, exempt from DGR declaration Non-replaceable battery
Configurable alarms 8 temperature alarm zones with single or cumulative delays, Alarm on MKT, Alarm on duration/run time
Start-up delay User configurable based on time or temperature
Display Multifunction LCD, size: 22 × 22 mm, with OK and Alarm indicator
Certificate Certificate available on demand
Optional: Additional customer-specific calibration points according to ISO 17025 standard
Traceability Unique ID number (traceable to component level)
Report Built-in PDF file generator automatically establishes an evaluation report with embedded data upon connection to a USB port.
Complies with the ISO standard 19005-1 Document Management for the long-term preservation of electronic documents (PDF/A) and FDA 21 CFR Part 11.
– Customizable report title and filename
– Text area for additional information (e.g. shipment information, instructions for recipient, etc.)
– Statistics (min/max, average, alarm, alarming on/off) and detailed logger information (ID, configuration, etc.)
– Chart visualizing the temperature curve and alarm limits
Case
Dimension
Weight
BS plastic material
95 × 41 × 11 mm (241.3 x 104.1 x 27.9 inch), cable tail 85 mm (3.35 inch) including M8 connector
44 g (0.1 lb)
Accessories LIBERO CE stainless steel bracket, variety of Pt100 probes, extension cable with M8 connector
Conformity
Standards
E | FCC | RoHS | Safe Transport of Chemical Goods | WEEE

RTCA DO-160 | GAMP5

Downloads
Contact Quote request