FK30 SL Calibration Baths

The calibration baths are perfectly suitable for applications in calibrationlaboratories and conform to the requirements specified by DIN ISO 9001.The instruments provide highest temperature stability and temperatureuniformity. An optional precision reference sensor with integrated measuringelectronics and RS232 connection is available.

Advantages:

  • VFD COMFORT DISPLAY
  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • Keypad for setpoints, warning/safety values and menu functions
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • Pt100 External sensor connection for measurement and control
  • SMART PUMP, electronically adjustable pump stages
  • Early warning system for low liquid level (DBGM 203 06 059.8)
  • Adjustable high temperature cut-out, visible via display
  • RS232/RS485 interface for online communication
  • Integrated programmer for 6 x 60 program steps
  • Highest temperature stability to ±0.005 °C (±0.02 °C at +200 °C)
  • Temperature uniformity better than ±0.01 °C
  • Optional Pt100 sensor for reference temperature measurements
  • Temperature chamber with overflow at maximum liquid levelActive Cooling Control
Model series HighTech
Category Calibration Baths
Working temperature range (°C) -30 … +200
Temperature stability (°C) ±0.005
Setting / display resolution 0.01
Integrated programmer 6×60 steps
Temperature Display VFD , LCD
Heating capacity (kW) 2
Cooling capacity (Medium Ethanol)
°C 20 0 -20
kW 0.46 0.34 0.15
Pump capacity flow rate (l/min) 22-26
Pump capacity flow pressure (bar) 0.4-0.7
Pump capacity flow suction (bar) 0.2-0.4
Bath opening / bath depth (W x L / D cm) Ø = 12 / 17 cm
Filling volume (liters) 14
Refrigerant stage 1 R134a
Filling volume refrigerant stage 1 (g) 163
Global Warming Potential for R134a 1430
Carbon dioxide equivalent stage 1 (t) 0.233
External Pt100 sensor connection integrated
Digital interfaces RS232
Optional Profibus
Ambient temperature 5…40 °C
Dimensions W x L x H (cm) 32 x 45 x 79
Weight (kg) 48
Classification according to DIN12876-1 Classification III (FL)
Included with each unit Including bath cover with 7 openings.
Bath cover integrated
Cooling of compressor Air
Overview

FK30 SL Calibration Baths

The calibration baths are perfectly suitable for applications in calibrationlaboratories and conform to the requirements specified by DIN ISO 9001.The instruments provide highest temperature stability and temperatureuniformity. An optional precision reference sensor with integrated measuringelectronics and RS232 connection is available.

Advantages:

  • VFD COMFORT DISPLAY
  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • Keypad for setpoints, warning/safety values and menu functions
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • Pt100 External sensor connection for measurement and control
  • SMART PUMP, electronically adjustable pump stages
  • Early warning system for low liquid level (DBGM 203 06 059.8)
  • Adjustable high temperature cut-out, visible via display
  • RS232/RS485 interface for online communication
  • Integrated programmer for 6 x 60 program steps
  • Highest temperature stability to ±0.005 °C (±0.02 °C at +200 °C)
  • Temperature uniformity better than ±0.01 °C
  • Optional Pt100 sensor for reference temperature measurements
  • Temperature chamber with overflow at maximum liquid levelActive Cooling Control
Technical Specifications
Model series HighTech
Category Calibration Baths
Working temperature range (°C) -30 … +200
Temperature stability (°C) ±0.005
Setting / display resolution 0.01
Integrated programmer 6×60 steps
Temperature Display VFD , LCD
Heating capacity (kW) 2
Cooling capacity (Medium Ethanol)
°C 20 0 -20
kW 0.46 0.34 0.15
Pump capacity flow rate (l/min) 22-26
Pump capacity flow pressure (bar) 0.4-0.7
Pump capacity flow suction (bar) 0.2-0.4
Bath opening / bath depth (W x L / D cm) Ø = 12 / 17 cm
Filling volume (liters) 14
Refrigerant stage 1 R134a
Filling volume refrigerant stage 1 (g) 163
Global Warming Potential for R134a 1430
Carbon dioxide equivalent stage 1 (t) 0.233
External Pt100 sensor connection integrated
Digital interfaces RS232
Optional Profibus
Ambient temperature 5…40 °C
Dimensions W x L x H (cm) 32 x 45 x 79
Weight (kg) 48
Classification according to DIN12876-1 Classification III (FL)
Included with each unit Including bath cover with 7 openings.
Bath cover integrated
Cooling of compressor Air
Download
Contact Quote request