MPRF Humidity
For processes that are sensitive to humidity, even small RH changes can dramatically affect product production, storage and shipping – impacting everything from production time to product quality to cost. To achieve optimal conditions, you need precise humidity data, preferably in real-time. With the DataTrace® MPRF Humidity Data Logger, you get it. The highly accurate MPRF Humidity Data Logger monitors RH across the full range, from 0% to 100% at temperatures from 0°C (32°F) to 85°C (185°F).
- Wireless temperature and humidity data logger
- Accurate across the full-range from 0%-100% at temperatures from 0°C to 85°C (32°F to 185°F)
- Memory for up to 8,000 data points – 4,000 for temperature and humidity readings
- FDA 21 CFR Part 11 Compliant
- Intrinsically Safe
Applications
Sterilization – Chilling – Freezing – Room Temperature – Pasteurization – EO Sterilization – Lyophilization –
MPRF Humidity |
|
Operating temperatures | +0°C to +85°C (+32°F to +185°F) |
Temperature accuracy | ± 0.1°C (±.2°F) |
Operating Humidity | 0% to 100% RH (non-condensing) |
Humidity Accuracy |
±2% RH non-condensing (±5% RH in EtO)
|
Resolution | 0.01% RH |
Wireless Range:
|
|
Radio Frequency:
|
|
Physical
|
|
Size:
|
Width: 0.91 in (23.2mm)
Length: 5.7 in (142.5
|
Weight:
|
4.0 oz (114 grams)
|
Material:
|
316 stainless steel and ULTEM
|
Sensor Elements
|
|
Temperature:
|
Thermistor
|
RH:
|
Capacitive Polymer
|
Mechanical
|
|
Calibration:
|
Factory calibrated (NIST traceable) or Field Calibration
|
Battery Type:
|
1/2 AA or Full AA Lithium (field-replaceable)
|
Battery Life:
|
6 months to 1 year (depending on usage)
|
Battery Weight:
|
0.6 oz (17 grams)
|
Clock accuracy:
|
10 seconds per 24 hours (25°C )
|
Certifications:
|
ATEX (for intrinsic safety)
FCC Class B digital device (part 15 compli
|
- Overview
-
MPRF Humidity
For processes that are sensitive to humidity, even small RH changes can dramatically affect product production, storage and shipping – impacting everything from production time to product quality to cost. To achieve optimal conditions, you need precise humidity data, preferably in real-time. With the DataTrace® MPRF Humidity Data Logger, you get it. The highly accurate MPRF Humidity Data Logger monitors RH across the full range, from 0% to 100% at temperatures from 0°C (32°F) to 85°C (185°F).
- Wireless temperature and humidity data logger
- Accurate across the full-range from 0%-100% at temperatures from 0°C to 85°C (32°F to 185°F)
- Memory for up to 8,000 data points – 4,000 for temperature and humidity readings
- FDA 21 CFR Part 11 Compliant
- Intrinsically Safe
Applications
Sterilization – Chilling – Freezing – Room Temperature – Pasteurization – EO Sterilization – Lyophilization –
- Technical Specifications
-
MPRF Humidity
Operating temperatures +0°C to +85°C (+32°F to +185°F) Temperature accuracy ± 0.1°C (±.2°F) Operating Humidity 0% to 100% RH (non-condensing) Humidity Accuracy ±2% RH non-condensing (±5% RH in EtO)Resolution 0.01% RH Wireless Range:Radio Frequency:PhysicalSize:Width: 0.91 in (23.2mm)Length: 5.7 in (142.5Weight:4.0 oz (114 grams)Material:316 stainless steel and ULTEMSensor ElementsTemperature:ThermistorRH:Capacitive PolymerMechanicalCalibration:Factory calibrated (NIST traceable) or Field CalibrationBattery Type:1/2 AA or Full AA Lithium (field-replaceable)Battery Life:6 months to 1 year (depending on usage)Battery Weight:0.6 oz (17 grams)Clock accuracy:10 seconds per 24 hours (25°C )Certifications:ATEX (for intrinsic safety)FCC Class B digital device (part 15 compli - Downloads