ATI 100X Automated Filter Tester

 

The ATI 100X Automated Filter Tester is designed for test and quality control validation of filter media, cartridges and masks used in medical and industrial hygiene applications. The 100X meets leading global industry standards such as NIOSH 42 CFR Part 84, GB 2626, EN 13274-7:2019, and ASTM F3502-21. The 100X is a high capacity automated solution ideally suited to meet the precise and rigorous requirements of both development and production quality control environments. The 100X is perfect for testing N95, KN95, FFP, and P100 respirator masks.

  • 100% Sampling Aerosol Detection System
  • Three flow rate options up to 170 L/min
  • Best-in-Class Differential Pressure Measurement Accuracy
  • Measure Filter Efficiency up to 99.9995%
  • Patented Aerosol Replenishment System Eliminates Production Downtime
  • Automatic, Hybrid & Manual Configurations
  • Quiet – Ideal for QC and R&D Labs

 

Application

  • Flat Sheet Filter Media
    • HEPA / ULPA Grade
    • Electret media
  • Filtering Face Pieces
  • Medical Device Filters
  • PAPR Filters
Performance & Product Specifications
Unit 100Xp (Oil) 100Xp (Paraffin) 100Xs (Salt)
Standards NIOSH 42CFR Part 84 or Equivalent EN13274-7:2019 NIOSH 42CFR Part 84 or Equivalent
Reagents DOP, PAO-4 Paraffin Oil NaCl
Primary Aerosol Reagent CAS# 8012-95-1
Density: 0.818 – 0.875 g/cm³
Dynamic Viscosity: 0.025Pa*s – 0.080 Pa*s
Kinematic Vicosity: <35mm²/s
Kinematic Viscosity: @40C: 13.5-16.5mm²/s
4% NaCl solution by weight
Replenishment Reagent 0.9% NaCl solution by weight
Available Configurations Manual, Hybrid and Automatic
Aerosol Generation
Particle Size
Count Median Diameter (CMD) 0.185μm ± 0.02 0.29 – 0.45μm 0.075 μm ± 0.02
Mass Mean Diameter (MMD) 0.3μm Not specified by the Standard 0.26 μm
Geometric Standard Deviation (GSD) ≤ 1.6 1.6 – 2.2 ≤ 1.86
Concentration (mg/m3) 80 – 120 15 – 25 15 – 25
Concentration (mg/m3) High Flow 40 – 60
Flow Rate Options 10 – 120 L/min (0.18 – 4.2 SCFM)
10 – 40 L/min (0.18 – 1.4 SCFM)
High Flow Option 10 – 170 L/min
(0.18 – 6.0 SCFM)
Aerosol Flow Accuracy Accurate to ± 0.4% of reading, plus ± 0.2% full scale
Aerosol Detection
Dynamic Range 0.1 μg/m³ to >200 mg/m³, accurate to ± 1% of reading
Penetration 0.0005%
Efficiency 99.9995%
Pressure Management
Pressure Range Options 0-25 mm H²O/0-245Pa
0-50 mm H²O/0-490Pa
0-100 mm H²O/0-981Pa
0-250 mm H²O/0-2452Pa
Accuracy ±0.25% of full scale
Test Fixture Standard Size: ID 11.4 cm (4.5”)
Stroke Height: 14.6 cm (5.75”)
Custom Test Fixture On Unit: ≤ 17.78 cm (7”) OD, 15.24 cm (6”) ID
Off Unit: No Size Limit
Communication Ports USB; RS232; Data Connection; PLC-Controls (Automatic, Hybrid version)
Utilities
Power 110VAC , 5.5A; or 220VAC, 2.5A (50/60 Hz)
Compressed Air 396 L/min at 6.2 bars ± 0.35 Bar (620 KPa ± 35 KPa)
or 14 SCFM at 90 psig ± 5.0 psig
Air Supply Line ID >9.5 mm (0.375”)
Dimensions (L x W x H)
100X Main Unit 71 cm x 69 cm x 89 cm (28” x 27” x 35”)
Optional Base 71 cm x 69 cm x 76 cm (27” x 28” x 30”)
Optional Exhaust 42.5 cm x 62.8 cm x 40.6 cm (16.75″ x 24.75″ x 16″)
Weight
100X Main Unit 75 kg (165 lbs)
Optional Base 38.6 kg (85 lbs)
Optional Local Exhaust 20 kg (44 lbs)
Compliance CE, RoHS, FCC, CSA
Overview

ATI 100X Automated Filter Tester

 

The ATI 100X Automated Filter Tester is designed for test and quality control validation of filter media, cartridges and masks used in medical and industrial hygiene applications. The 100X meets leading global industry standards such as NIOSH 42 CFR Part 84, GB 2626, EN 13274-7:2019, and ASTM F3502-21. The 100X is a high capacity automated solution ideally suited to meet the precise and rigorous requirements of both development and production quality control environments. The 100X is perfect for testing N95, KN95, FFP, and P100 respirator masks.

  • 100% Sampling Aerosol Detection System
  • Three flow rate options up to 170 L/min
  • Best-in-Class Differential Pressure Measurement Accuracy
  • Measure Filter Efficiency up to 99.9995%
  • Patented Aerosol Replenishment System Eliminates Production Downtime
  • Automatic, Hybrid & Manual Configurations
  • Quiet – Ideal for QC and R&D Labs

 

Application

  • Flat Sheet Filter Media
    • HEPA / ULPA Grade
    • Electret media
  • Filtering Face Pieces
  • Medical Device Filters
  • PAPR Filters
Technical specification
Performance & Product Specifications
Unit 100Xp (Oil) 100Xp (Paraffin) 100Xs (Salt)
Standards NIOSH 42CFR Part 84 or Equivalent EN13274-7:2019 NIOSH 42CFR Part 84 or Equivalent
Reagents DOP, PAO-4 Paraffin Oil NaCl
Primary Aerosol Reagent CAS# 8012-95-1
Density: 0.818 – 0.875 g/cm³
Dynamic Viscosity: 0.025Pa*s – 0.080 Pa*s
Kinematic Vicosity: <35mm²/s
Kinematic Viscosity: @40C: 13.5-16.5mm²/s
4% NaCl solution by weight
Replenishment Reagent 0.9% NaCl solution by weight
Available Configurations Manual, Hybrid and Automatic
Aerosol Generation
Particle Size
Count Median Diameter (CMD) 0.185μm ± 0.02 0.29 – 0.45μm 0.075 μm ± 0.02
Mass Mean Diameter (MMD) 0.3μm Not specified by the Standard 0.26 μm
Geometric Standard Deviation (GSD) ≤ 1.6 1.6 – 2.2 ≤ 1.86
Concentration (mg/m3) 80 – 120 15 – 25 15 – 25
Concentration (mg/m3) High Flow 40 – 60
Flow Rate Options 10 – 120 L/min (0.18 – 4.2 SCFM)
10 – 40 L/min (0.18 – 1.4 SCFM)
High Flow Option 10 – 170 L/min
(0.18 – 6.0 SCFM)
Aerosol Flow Accuracy Accurate to ± 0.4% of reading, plus ± 0.2% full scale
Aerosol Detection
Dynamic Range 0.1 μg/m³ to >200 mg/m³, accurate to ± 1% of reading
Penetration 0.0005%
Efficiency 99.9995%
Pressure Management
Pressure Range Options 0-25 mm H²O/0-245Pa
0-50 mm H²O/0-490Pa
0-100 mm H²O/0-981Pa
0-250 mm H²O/0-2452Pa
Accuracy ±0.25% of full scale
Test Fixture Standard Size: ID 11.4 cm (4.5”)
Stroke Height: 14.6 cm (5.75”)
Custom Test Fixture On Unit: ≤ 17.78 cm (7”) OD, 15.24 cm (6”) ID
Off Unit: No Size Limit
Communication Ports USB; RS232; Data Connection; PLC-Controls (Automatic, Hybrid version)
Utilities
Power 110VAC , 5.5A; or 220VAC, 2.5A (50/60 Hz)
Compressed Air 396 L/min at 6.2 bars ± 0.35 Bar (620 KPa ± 35 KPa)
or 14 SCFM at 90 psig ± 5.0 psig
Air Supply Line ID >9.5 mm (0.375”)
Dimensions (L x W x H)
100X Main Unit 71 cm x 69 cm x 89 cm (28” x 27” x 35”)
Optional Base 71 cm x 69 cm x 76 cm (27” x 28” x 30”)
Optional Exhaust 42.5 cm x 62.8 cm x 40.6 cm (16.75″ x 24.75″ x 16″)
Weight
100X Main Unit 75 kg (165 lbs)
Optional Base 38.6 kg (85 lbs)
Optional Local Exhaust 20 kg (44 lbs)
Compliance CE, RoHS, FCC, CSA
Download
Contact Quote request