USRIC-8

USB temperature data logger-30°C to +60°C

USCRIC-8 data logger with integral USB connector. Ideal for cost-effective monitoring of temperature sensitive goods in both short haul and long-distance transportation applications

Product Highlights

  • Integral USB connector – No separate Interface Cradle required
  • Automatically generates a PDF report – No special software required
  • Encrypted LTD file generated for a more detailed analysis
  • User configurable – No need to buy a special logger for each trip
  • Suitable for independent receivers, clinical trials & last-mile distribution

Applications

Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room – Clinical Trials

USRIC-8

Sensor Measurement Range -30°C to +60°C (-13°F to +140°F).
Operating Temperature Range -30°C to +60°C (-13°F to +140°F).
Storage Temperature Range 0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Accuracy Better than ±0.5°C for -5°C to +30°C.
Better than ±0.8°C or better for measurements in other areas of rated range.
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution Less than 0.1°C/F.
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 5 minutes (T90) in moving air (1m/s).
Recording Capacity 8,001 temperature readings. 26.6 days @ 5min logging, 80 days @ 15min logging.
Sampling Interval Configurable from 1 minute to 18 hours.
Logging Start Options Push button start or specific date & time.
Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
Download Time Typically with full memory (8,001 readings) in less than 20 seconds from time of insertion to availability of PDF report.
Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured).
Environmental IEC 60529: IP64 with USB cap fitted.
Power Source 3V Li-Mg Battery.
Battery Life Shelf life of up to two years before configuration. Six months operating life from the time of configuration.
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Connection Interface USB 2.0, A-type plug.
Software PDF Reader, LogTag® Analyzer 2.5 or higher.
Size 93mm(H) x 54.5mm(W) x 8.6mm(T) including protective USB cap.
Weight 31g.
Case Material Polycarbonate.
Compliance and Certifications CFRPart11FCCCE  RoHS
Overview

USRIC-8

USB temperature data logger-30°C to +60°C

USCRIC-8 data logger with integral USB connector. Ideal for cost-effective monitoring of temperature sensitive goods in both short haul and long-distance transportation applications

Product Highlights

  • Integral USB connector – No separate Interface Cradle required
  • Automatically generates a PDF report – No special software required
  • Encrypted LTD file generated for a more detailed analysis
  • User configurable – No need to buy a special logger for each trip
  • Suitable for independent receivers, clinical trials & last-mile distribution

Applications

Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room – Clinical Trials

Technical Specifications

USRIC-8

Sensor Measurement Range -30°C to +60°C (-13°F to +140°F).
Operating Temperature Range -30°C to +60°C (-13°F to +140°F).
Storage Temperature Range 0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Accuracy Better than ±0.5°C for -5°C to +30°C.
Better than ±0.8°C or better for measurements in other areas of rated range.
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution Less than 0.1°C/F.
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 5 minutes (T90) in moving air (1m/s).
Recording Capacity 8,001 temperature readings. 26.6 days @ 5min logging, 80 days @ 15min logging.
Sampling Interval Configurable from 1 minute to 18 hours.
Logging Start Options Push button start or specific date & time.
Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
Download Time Typically with full memory (8,001 readings) in less than 20 seconds from time of insertion to availability of PDF report.
Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured).
Environmental IEC 60529: IP64 with USB cap fitted.
Power Source 3V Li-Mg Battery.
Battery Life Shelf life of up to two years before configuration. Six months operating life from the time of configuration.
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Connection Interface USB 2.0, A-type plug.
Software PDF Reader, LogTag® Analyzer 2.5 or higher.
Size 93mm(H) x 54.5mm(W) x 8.6mm(T) including protective USB cap.
Weight 31g.
Case Material Polycarbonate.
Compliance and Certifications CFRPart11FCCCE  RoHS