TRED 30-16R

Display temperature data logger -40°C to +99°C

Temperature measurement where access requires a remote probe and data needs to be accessed without a PC.

The alarm is triggered if temperature readings are outside pre-set alarm limits. The status indicator changes from a ✔ to a X and, if configured, the audible alarm will sound. The day marker will also appear if not already present. The alarm status indicator and audible alarm can be easily cleared, but the day marker remains to ensure a visible record of excursions is shown on the display. A simplified alarm clearance, stop & start procedure is available as an option.

Product Highlights

  • Data logging Records time and temperature data for later download.
  • State Indicators Display shows current state (READY,STARTING,RECORDING, PAUSED or STOPPED).
  • Built-in Audible Alarm
  • Alarm Symbol Appears on the display to show an alarm trigger has occurred.
  • Day alarm summary Displays in calendar-like format alarm triggers for up to the last 30days.
  • Current time & temperature Shows the current time and the last recorded temperature when not in review mode.
  • Review button Allows review of current day and up to 29 previous days of statistical data and also adds an ‘inspection mark’ into the recordings.
  • Start/Clear/Stop button Push button recording start, alarm clear and recording stop (each option separately configurable).
  • Flexible start options Push button recording start with optional delayed start (up to 18 hours) or specific time & date start.
  • Flexible recording options Either record for a fixed time or record continuously with ‘wrap around logging’.
  • Rapid Download! Takes only seconds to download recordings.
  • Thin flat case Fits easily into packaging and thin enough to be easily mailed “letter rate”.
  • Real time clock Records time & temperature simultaneously.
  • 15.900 recordings capacity Enough memory for 66 days @ 6min logging.
  • High Quality Connector Gold plated remote probe connector.
  • Interchangeable Probes LogTag® remote temperature ST100 probes are interchangeable.

 

Applications

Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room

TRED30-16R (Replaceable Battery)

External Sensor Measurement Range -40°C to +99°C (-40°F to +210°F).
Operating Temperature Range -30°C to +60°C (-22°F to +140°F).
Storage Temperature Range -10°C to +40°C (14°F to +104°F).
Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F).
Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F).
Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F).
Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F).
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution 0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F).
0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F).
0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F).
0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F).
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T, ST100H and ST100S types.
Recording Capacity 15,905 temperature readings. 66 days @ 6min logging.
Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics.
Sampling Interval Configurable from 30 seconds to hourly.
Logging Start Options Push button start or specific date & time. Optional start delay of up to 18 hours.
Recording Indication State indicator “RECORDING”.
Download Time Typically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used.
Environmental IP61 (when vertically mounted or hung).
Power Source 3V CR2032 (LiMnO2) coin cell battery, user replaceable.
Battery Life Typically 1 year of operation.
NOTE: Typical battery life assumes 6 minute logging, day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time.
Download data monthly.
NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible.
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Standard Remote Sensor Cable Length Standard: 1.5m (4’11″).
Extended: 3m (9’10″) (Recommended maximum).
Remote Sensor Cable Type PTFE (FDA food contact rated), coaxial.
Size 93mm(H) x 54.5mm(W) x 8.6mm(T).
Weight 41g.
Case Material Polycarbonate.
Compliance and Certifications CFRPart11  FCCCE   RoHS
Overview

TRED 30-16R

Display temperature data logger -40°C to +99°C

Temperature measurement where access requires a remote probe and data needs to be accessed without a PC.

The alarm is triggered if temperature readings are outside pre-set alarm limits. The status indicator changes from a ✔ to a X and, if configured, the audible alarm will sound. The day marker will also appear if not already present. The alarm status indicator and audible alarm can be easily cleared, but the day marker remains to ensure a visible record of excursions is shown on the display. A simplified alarm clearance, stop & start procedure is available as an option.

Product Highlights

  • Data logging Records time and temperature data for later download.
  • State Indicators Display shows current state (READY,STARTING,RECORDING, PAUSED or STOPPED).
  • Built-in Audible Alarm
  • Alarm Symbol Appears on the display to show an alarm trigger has occurred.
  • Day alarm summary Displays in calendar-like format alarm triggers for up to the last 30days.
  • Current time & temperature Shows the current time and the last recorded temperature when not in review mode.
  • Review button Allows review of current day and up to 29 previous days of statistical data and also adds an ‘inspection mark’ into the recordings.
  • Start/Clear/Stop button Push button recording start, alarm clear and recording stop (each option separately configurable).
  • Flexible start options Push button recording start with optional delayed start (up to 18 hours) or specific time & date start.
  • Flexible recording options Either record for a fixed time or record continuously with ‘wrap around logging’.
  • Rapid Download! Takes only seconds to download recordings.
  • Thin flat case Fits easily into packaging and thin enough to be easily mailed “letter rate”.
  • Real time clock Records time & temperature simultaneously.
  • 15.900 recordings capacity Enough memory for 66 days @ 6min logging.
  • High Quality Connector Gold plated remote probe connector.
  • Interchangeable Probes LogTag® remote temperature ST100 probes are interchangeable.

 

Applications

Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room

Technical Specifications

TRED30-16R (Replaceable Battery)

External Sensor Measurement Range -40°C to +99°C (-40°F to +210°F).
Operating Temperature Range -30°C to +60°C (-22°F to +140°F).
Storage Temperature Range -10°C to +40°C (14°F to +104°F).
Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F).
Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F).
Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F).
Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F).
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution 0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F).
0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F).
0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F).
0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F).
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T, ST100H and ST100S types.
Recording Capacity 15,905 temperature readings. 66 days @ 6min logging.
Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics.
Sampling Interval Configurable from 30 seconds to hourly.
Logging Start Options Push button start or specific date & time. Optional start delay of up to 18 hours.
Recording Indication State indicator “RECORDING”.
Download Time Typically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used.
Environmental IP61 (when vertically mounted or hung).
Power Source 3V CR2032 (LiMnO2) coin cell battery, user replaceable.
Battery Life Typically 1 year of operation.
NOTE: Typical battery life assumes 6 minute logging, day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time.
Download data monthly.
NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible.
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Standard Remote Sensor Cable Length Standard: 1.5m (4’11″).
Extended: 3m (9’10″) (Recommended maximum).
Remote Sensor Cable Type PTFE (FDA food contact rated), coaxial.
Size 93mm(H) x 54.5mm(W) x 8.6mm(T).
Weight 41g.
Case Material Polycarbonate.
Compliance and Certifications CFRPart11  FCCCE   RoHS
Downloads
Contact Quote request