TP 18850E
SIKA temperature calibrators can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. They cover a broad spectrum of industries with diverse applications.
Dry block function
The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and diameter can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flash points or outgassing are of no concern.
Applications
Pharmaceuticals – Produce/Meat/Dairy – Chemicals – Laboratories – Assembly and commissioning – Manufacturing and production – Maintenance and service – Quality assurance and test equipment monitoring – Repair
TP 18850 E |
|
Dry block | |
Temperature range* | Room Temperature* to 850 °C |
Tolerance | ±1 °C |
Stability | ±0,1 °C |
Resolution | 1 °C |
Reference temperature sensor | internal, fixed installation |
Dimensions | Width :330 mm + 70 mm (Handle) Height : 270 mm Depth : 150 mm |
Weight | Approx. 14 kg |
Display | 2-line, 4-digit display red / green, unit °C / °F |
Dimension of the calibration insert | Ø 18 x 100 mm (calibration insert easily exchangeable) |
* At an ambient temperature of 20 °C / 68 °F
- Overview
-
TP 18850E
SIKA temperature calibrators can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. They cover a broad spectrum of industries with diverse applications.
Dry block function
The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and diameter can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flash points or outgassing are of no concern.Applications
Pharmaceuticals – Produce/Meat/Dairy – Chemicals – Laboratories – Assembly and commissioning – Manufacturing and production – Maintenance and service – Quality assurance and test equipment monitoring – Repair
- Technical Specifications
-
TP 18850 E
Dry block Temperature range* Room Temperature* to 850 °C Tolerance ±1 °C Stability ±0,1 °C Resolution 1 °C Reference temperature sensor internal, fixed installation Dimensions Width :330 mm + 70 mm (Handle)
Height : 270 mm
Depth : 150 mm
Weight Approx. 14 kg Display 2-line, 4-digit display
red / green, unit °C / °FDimension of the calibration insert Ø 18 x 100 mm (calibration insert easily exchangeable) * At an ambient temperature of 20 °C / 68 °F