Libero CB
The most Cost-effective Cold Chain Monitoring Solution and Database
LIBERO CB is the universal PDF Logger for almost any cold chain monitoring challenge. Whether you require strict upper and lower alarm limits, alarm on MKT or duration, LIBERO CB offers it all and allows you to individually set these limits.
No need to keep different loggers in stock. Simply apply the correct configuration profile and add shipment information at the time of use and send off the logger. No equipment is required and no software needs to be installed. Read the PDF report and forward it to the sender or to liberoMANAGER, ELPRO’s cold chain database, for further analysis.
Applications
Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room
Libero CB
|
|
Application area | Cold Chain Monitoring – applications monitored with strict alarm limits, MKT or time |
Recording options and mode | Single use: start / stop mode |
Type of probe | Internal NTC probe |
Operating range | -20°C to +70°C |
Measurement accuracy | ± 0.3 °C typ. in the range of -10 °C..+25 °C |
Resolution | 0.1 °C |
Measurement interval | 1 to 60 minutes, user programmable |
Memory capacity | 8’800 measurement values (equals 60 days run time with 10 min interval) |
Expiry date and battery life | – Data logger can be started any time during shelf life of 12 months – Started data logger runs until memory is full or logger is stopped – Auto expiry date management: After expiry, display changes status and logger cannot be started anymore – Long time operating range: -10°C..+50°C for entire shelf life – Extended operating range: 10 days at -20°C and 10 days at +70°C – Use beyond the extended operating range can limit the battery |
Certificate | 12 month certificate with reference to sensor calibration and data logger test results |
Programmable alarms | – 2 temperature thresholds with alarm delay – Alarm on MKT – Alarm on duration / run time |
Start-up delay | 0 minutes to 24 h |
Display | Multifunction LCD, size: 23.5 x 23.5 mm, with large OK and ALARM indicator |
Display functionality | Built-in PDF file generator automatically establishes an evaluation report with embedded data upon connection to a USB port. Complies with the ISO standard 19005-1 Document Management for the long-term preservation of electronic documents (PDF/A) and FDA 21 CFR Part 11. – Customizable report title and filename – Text area for additional information (e.g. shipment information, instructions for recipient, etc.) – Immediate release or quarantine based on alarm status – Statistics (min/max, average, alarm) and detailed logger information (ID, configuration, etc.) – Chart visualizing the temperature curve and alarm limits |
Report | |
Data logger configuration and additional analysis software | liberoCONFIG software to create, store and manage individual settings in a logger profile as well as SmartStart, a liberoCONFIG component allowing a safe and quick application of profiles and shipment information to PDF Logger. elproVIEWER software to access and export embedded data of PDF report, for data analysis and comprehensive report features. Both software products downloadable free of charge. |
Case Dimension Weight |
ABS plastic material 6 x 37 x 11 mm (3.8 x 1.5 x 0.5 inch) 38 g |
- Overview
-
Libero CB
The most Cost-effective Cold Chain Monitoring Solution and Database
LIBERO CB is the universal PDF Logger for almost any cold chain monitoring challenge. Whether you require strict upper and lower alarm limits, alarm on MKT or duration, LIBERO CB offers it all and allows you to individually set these limits.
No need to keep different loggers in stock. Simply apply the correct configuration profile and add shipment information at the time of use and send off the logger. No equipment is required and no software needs to be installed. Read the PDF report and forward it to the sender or to liberoMANAGER, ELPRO’s cold chain database, for further analysis.Applications
Cold Chain – Pharmaceuticals – Produce/Meat/Dairy – Agriculture & Floral – Office & Warehouse – Museums – Chemicals – Laboratories – Server room
- Technical Specifications
-
Libero CB
Application area Cold Chain Monitoring – applications monitored with strict alarm limits, MKT or time Recording options and mode Single use: start / stop mode Type of probe Internal NTC probe Operating range -20°C to +70°C Measurement accuracy ± 0.3 °C typ. in the range of -10 °C..+25 °C Resolution 0.1 °C Measurement interval 1 to 60 minutes, user programmable Memory capacity 8’800 measurement values (equals 60 days run time with 10 min interval) Expiry date and battery life – Data logger can be started any time during shelf life of 12 months
– Started data logger runs until memory is full or logger is stopped
– Auto expiry date management: After expiry, display changes status and logger cannot be started anymore
– Long time operating range: -10°C..+50°C for entire shelf life
– Extended operating range: 10 days at -20°C and 10 days at +70°C
– Use beyond the extended operating range can limit the batteryCertificate 12 month certificate with reference to sensor calibration and data logger test results Programmable alarms – 2 temperature thresholds with alarm delay
– Alarm on MKT
– Alarm on duration / run timeStart-up delay 0 minutes to 24 h Display Multifunction LCD, size: 23.5 x 23.5 mm, with large OK and ALARM indicator Display functionality Built-in PDF file generator automatically establishes an evaluation report with embedded data upon
connection to a USB port. Complies with the ISO standard 19005-1 Document Management for the
long-term preservation of electronic documents (PDF/A) and FDA 21 CFR Part 11.
– Customizable report title and filename
– Text area for additional information (e.g. shipment information, instructions for recipient, etc.)
– Immediate release or quarantine based on alarm status
– Statistics (min/max, average, alarm) and detailed logger information (ID, configuration, etc.)
– Chart visualizing the temperature curve and alarm limitsReport Data logger configuration and additional analysis software liberoCONFIG software to create, store and manage individual settings in a logger profile as well as SmartStart, a liberoCONFIG component allowing a safe and quick application of profiles and shipment information to PDF Logger. elproVIEWER software to access and export embedded data of PDF report,
for data analysis and comprehensive report features.
Both software products downloadable free of charge.Case
Dimension
WeightABS plastic material
6 x 37 x 11 mm (3.8 x 1.5 x 0.5 inch)
38 g - Downloads