MPIII Pressure
Part of DataTrace’s comprehensive solution, the wireless MPIII Pressure Data Logger requires minimal training to use. Features like IR communication and batch programming in just seconds make setup fast and simple. And it can collect up to 16,000 data points – 8,000 each for pressure and temperature readings – allowing for exceptional detail.
- 10 Point Pressure NIST Traceable Calibration
- 14 Point Temp NIST Traceable Calibration
- Compact Size (1.9” x 0.7”)
- FDA 21 CFR Part 11 Compliant Software
With a body measuring just 1.9 inches long, MPIII Pressure Data Loggers fit inside containers to get pressure readings from 0 PSIA (0 BAR) to 72.5 PSIA (5 BAR) with exceptional accuracy of ± 0.45 PSIA (± 0.03 BAR) at temperatures ranging from 25°C (77°F) to 140°C (284°F). With their wide range and high precision, MPIII Pressure Data Loggers are not only well suited to canningand pouch processes, but an array of applications where pressure affects products and quality.
Applications
MPIII Pressure |
|
Operating Temperature:
|
+25°C to +140°C (+77°F to +284°F)
|
Temperature Accuracy:
|
±0.25°C (±0.45°F)
|
Resolution:
|
0.001 PSI
|
Operating Pressure:
|
0 PSIA (0 BAR) to 72.5 PSIA (5 BAR)
|
Pressure Accuracy:
|
± 0.45 PSIA (± 0.03 BAR)
|
Size:
|
Width: 0.7 in (18mm)
Length: 1.9 in (48mm)
|
Weight:
|
1.9 oz (55 grams)
|
Material: |
316 stainless steel; Sapphire IR windows
|
Sensor Elements | |
Temperature: | Thermistor |
Pressure: | Strain gauge bridge |
Mechanical | |
Media:
|
Compatible with air and fluids, including many corrosive liquids
|
Calibration:
|
Factory calibrated (NIST traceable)
|
Battery Type:
|
Lithium (field-replaceable)
|
Clock accuracy:
|
26 seconds per 24 hours
|
Certifications:
|
ATEX (for intrinsic safety) – under review – to be certified soon
|
Monitoring Parameters | |
Memory
|
8,000 time/temperature observations and 8,000 time/pressure observations
|
Sample rates | Operator programmable 1 sec. to 1 hr. intervals |
- Overview
-
MPIII Pressure
Part of DataTrace’s comprehensive solution, the wireless MPIII Pressure Data Logger requires minimal training to use. Features like IR communication and batch programming in just seconds make setup fast and simple. And it can collect up to 16,000 data points – 8,000 each for pressure and temperature readings – allowing for exceptional detail.
- 10 Point Pressure NIST Traceable Calibration
- 14 Point Temp NIST Traceable Calibration
- Compact Size (1.9” x 0.7”)
- FDA 21 CFR Part 11 Compliant Software
With a body measuring just 1.9 inches long, MPIII Pressure Data Loggers fit inside containers to get pressure readings from 0 PSIA (0 BAR) to 72.5 PSIA (5 BAR) with exceptional accuracy of ± 0.45 PSIA (± 0.03 BAR) at temperatures ranging from 25°C (77°F) to 140°C (284°F). With their wide range and high precision, MPIII Pressure Data Loggers are not only well suited to canningand pouch processes, but an array of applications where pressure affects products and quality.
Applications
Foods – Canning – Beverages, wine & soda production – Pharmaceuticals – Autoclaves – EtO sterilization – Monitoring & Testing compressed gas systems – Pressurized process reactors and streams - Technical Specifications
-
MPIII Pressure
Operating Temperature:+25°C to +140°C (+77°F to +284°F)Temperature Accuracy:±0.25°C (±0.45°F)Resolution:0.001 PSIOperating Pressure:0 PSIA (0 BAR) to 72.5 PSIA (5 BAR)Pressure Accuracy:± 0.45 PSIA (± 0.03 BAR)Size: Width: 0.7 in (18mm)Length: 1.9 in (48mm)Weight:1.9 oz (55 grams)Material: 316 stainless steel; Sapphire IR windowsSensor Elements Temperature: Thermistor Pressure: Strain gauge bridge Mechanical Media:Compatible with air and fluids, including many corrosive liquidsCalibration:Factory calibrated (NIST traceable)Battery Type:Lithium (field-replaceable)Clock accuracy:26 seconds per 24 hoursCertifications:ATEX (for intrinsic safety) – under review – to be certified soonMonitoring Parameters Memory 8,000 time/temperature observations and 8,000 time/pressure observationsSample rates Operator programmable 1 sec. to 1 hr. intervals - Downloads