Part of DataTrace’s comprehensive solution, the wireless MPIII Pressure Data Logger requires minimal training to use. Features like IR communication and batch programming in just seconds make setup fast and simple. And it can collect up to 16,000 data points – 8,000 each for pressure and temperature readings – allowing for exceptional detail.

  • 10 Point Pressure NIST Traceable Calibration
  • 14 Point Temp NIST Traceable Calibration
  • Compact Size (1.9” x 0.7”)
  • FDA 21 CFR Part 11 Compliant Software

With a body measuring just 1.9 inches long, MPIII Pressure Data Loggers fit inside containers to get pressure readings from 0 PSIA (0 BAR) to 72.5 PSIA (5 BAR) with exceptional accuracy of ± 0.45 PSIA (± 0.03 BAR) at temperatures ranging from 25°C (77°F) to 140°C (284°F). With their wide range and high precision, MPIII Pressure Data Loggers are not only well suited to canningand pouch processes, but an array of applications where pressure affects products and quality.

Applications

Foods – Canning – Beverages, wine & soda production – Pharmaceuticals – Autoclaves – EtO sterilization – Monitoring & Testing compressed gas systems – Pressurized process reactors and streams

MPIII Pressure

 

Operating Temperature:
+25°C to +140°C (+77°F to +284°F)
Temperature Accuracy:
±0.25°C (±0.45°F)
Resolution:
0.001 PSI
Operating Pressure:
0 PSIA (0 BAR) to 72.5 PSIA (5 BAR)
Pressure Accuracy:
± 0.45 PSIA (± 0.03 BAR)
Size:

 

Width: 0.7 in (18mm)
Length: 1.9 in (48mm)
Weight:
1.9 oz (55 grams)
Material:
316 stainless steel; Sapphire IR windows
Sensor  Elements
Temperature: Thermistor
Pressure: Strain gauge bridge
Mechanical
Media:
Compatible with air and fluids, including many corrosive liquids
Calibration:
Factory calibrated (NIST traceable)
Battery Type:
Lithium (field-replaceable)
Clock accuracy:
26 seconds per 24 hours
Certifications:
ATEX (for intrinsic safety) – under review – to be certified soon
Monitoring Parameters
Memory

 

8,000 time/temperature observations and 8,000 time/pressure observations
Sample rates Operator programmable 1 sec. to 1 hr. intervals
Overview

MPIII Pressure

Part of DataTrace’s comprehensive solution, the wireless MPIII Pressure Data Logger requires minimal training to use. Features like IR communication and batch programming in just seconds make setup fast and simple. And it can collect up to 16,000 data points – 8,000 each for pressure and temperature readings – allowing for exceptional detail.

  • 10 Point Pressure NIST Traceable Calibration
  • 14 Point Temp NIST Traceable Calibration
  • Compact Size (1.9” x 0.7”)
  • FDA 21 CFR Part 11 Compliant Software

With a body measuring just 1.9 inches long, MPIII Pressure Data Loggers fit inside containers to get pressure readings from 0 PSIA (0 BAR) to 72.5 PSIA (5 BAR) with exceptional accuracy of ± 0.45 PSIA (± 0.03 BAR) at temperatures ranging from 25°C (77°F) to 140°C (284°F). With their wide range and high precision, MPIII Pressure Data Loggers are not only well suited to canningand pouch processes, but an array of applications where pressure affects products and quality.

Applications

Foods – Canning – Beverages, wine & soda production – Pharmaceuticals – Autoclaves – EtO sterilization – Monitoring & Testing compressed gas systems – Pressurized process reactors and streams
Technical Specifications

MPIII Pressure

 

Operating Temperature:
+25°C to +140°C (+77°F to +284°F)
Temperature Accuracy:
±0.25°C (±0.45°F)
Resolution:
0.001 PSI
Operating Pressure:
0 PSIA (0 BAR) to 72.5 PSIA (5 BAR)
Pressure Accuracy:
± 0.45 PSIA (± 0.03 BAR)
Size:

 

Width: 0.7 in (18mm)
Length: 1.9 in (48mm)
Weight:
1.9 oz (55 grams)
Material:
316 stainless steel; Sapphire IR windows
Sensor  Elements
Temperature: Thermistor
Pressure: Strain gauge bridge
Mechanical
Media:
Compatible with air and fluids, including many corrosive liquids
Calibration:
Factory calibrated (NIST traceable)
Battery Type:
Lithium (field-replaceable)
Clock accuracy:
26 seconds per 24 hours
Certifications:
ATEX (for intrinsic safety) – under review – to be certified soon
Monitoring Parameters
Memory

 

8,000 time/temperature observations and 8,000 time/pressure observations
Sample rates Operator programmable 1 sec. to 1 hr. intervals